All categories
Compare Cart

XC2JC163 - Limit switch, Limit switches XC Standard, XC2 J, metal side plunger, 1 C/O - Schneider Electric

Expected in 2-4 weeks
XC2JC163 - Limit switch, Limit switches XC Standard, XC2 J, metal side plunger, 1 C/O - Schneider Electric - Limit switch, Limit switches XC Standard, XC2 J, metal side plunger, 1 C/O - Schneider Electric - 0
XC2JC163 - Limit switch, Limit switches XC Standard, XC2 J, metal side plunger, 1 C/O - Schneider Electric
112,50 €
112,50 € incl. VAT
Text About:
Limit switch, Limit switches XC Standard, XC2 J, metal side plunger, 1 C/O - Schneider Electric
112,50 €
SPECIFICATIONS
Main
Body type Fixed
Device short name XC2J
product specific application For severe applications
[ui] rated insulation voltage 500 V conforming to IEC 60947-5-1
500 V conforming to NF C 20-040 group C
300 V conforming to CSA C22.2 No 14
Series name Special format
head type Plunger head
Complementary
Product certifications CSA
NEMKO
DEMKO
Handle front plate colour 112 mm
Product or component type Limit switch
cable entry 1 entry incorporating cable gland, cable outer diameter: 6…13.5 mm
Contacts insulation form Za
Contacts material Silver plated contacts
contact operation Snap action
Electrical shock protection class Class I conforming to IEC 60536
Class I conforming to NF C 20-030
Fixing mode By the body
Material Metal
width (w) 40 mm
Type of operator Side plunger metal
Ik degree of protection IK08
contact code designation A300, AC-15 (Ue = 240 V), Ie = 3 A, Ithe = 10 A conforming to EN/IEC 60947-5-1
Q300, DC-13 (Ue = 250 V), Ie = 0.27 A conforming to EN/IEC 60947-5-1
Net weight 0.6 kg
depth 41 mm
mechanical durability 30000000 cycles
electrical durability 5000000 cycles, DC-13, 120 V, 4 W, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 24 V, 10 W, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
5000000 cycles, DC-13, 48 V, 7 W, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C
repeat accuracy 0.01 mm with 1 million operating cycles
Maximum actuation speed 0.5 m/s
Positive opening Without
electrical connection Screw-clamp terminals, clamping capacity: 1 x 0.5...2 x 2.5 mm²
Maximum resistance across terminals 25 MOhm conforming to IEC 60255-7 category 3
25 MOhm conforming to NF C 93-050 method A
Minimum actuation speed 0.001 m/min
Minimum force for tripping 26 N
Movement of operating head Linear
Switch actuation On end
Type of approach Lateral approach, 1 direction
Shock resistance 25 gn for 18 ms conforming to IEC 60068-2-27
Poles description 1
Short-circuit protection 10 A cartridge fuse, type gG
Terminals description iso n°1 (13-14-11-12)DE
Environment
Ambient air temp for storage/transportation -40…70 °C
ip degree of protection IP65 conforming to IEC 60529
IP657 conforming to NF C 20-010
Range of product OsiSense XC
ambient air temperature for operation -25…70 °C
standards EN/IEC 60947-5-1
IEC 60337-1
UL 508
VDE 0660-200
CSA C22.2 No 14
vibration resistance 10 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment TC
Recently viewed
112,50 €
112,50 € incl. VAT
Expected in 2-4 weeks