Complementary
[ie] rated operational current
3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1
0.1 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1
0.22 A at 125 V, DC-13, R300 conforming to EN/IEC 60947-5-1
Product certifications
CSA
CCC
GOST
UL
Handle front plate colour
30 mm
mounting diameter
16 mm
Product or component type
Complete emergency stop push-button
[uimp] rated impulse withstand voltage
4 kV conforming to EN/IEC 60947-1
nema degree of protection
NEMA 13 conforming to UL 50
NEMA 4 conforming to UL 50
NEMA 4X conforming to UL 50
NEMA 13 conforming to CSA C22.2 No 94
NEMA 4X conforming to CSA C22.2 No 94
NEMA 4 conforming to CSA C22.2 No 94
Connections - terminals
Faston connectors, connection size: 2.8 x 0.5 mm
bezel material
Plastic
Contacts material
Silver alloy (Ag/Ni)
contact operation
Slow-break
Contacts type and composition
1 NO + 2 NC
Electrical shock protection class
Class II conforming to IEC 61140
Operating travel
1 mm (NC changing electrical state)
2 mm (NO changing electrical state)
3.5 mm (total travel)
Sale per indivisible quantity
1
width (w)
30 mm
electrical reliability
Λ < 10exp(-8) at 5 V, 1 mA with confidence level of 90 % conforming to IEC 60947-5-4
Type of operator
trigger action and mechanical latching
Contacts usage
Standard
Net weight
0.041 kg
Operating position
Any position
depth
77 mm
mechanical durability
100000 cycles
electrical durability
1000000 cycles, AC-15 at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13 at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
Positive opening
With conforming to EN/IEC 60947-5-1 appendix K
Shape of signaling unit head
Round
Operating force
3.5 N NO changing electrical state
4.5 N NC changing electrical state
Operator profile
Red mushroom Ø 30 mm, unmarked
Shock resistance
30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Short-circuit protection
6 A cartridge fuse type gG
Type of keylock
Ronis 200
Terminals description iso n°1
(31-32)NC
(13-14)NON
(21-22)NC
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP65 conforming to IEC 60529
Range of product
Harmony XB6
ambient air temperature for operation
-25…70 °C
standards
UL 508
JIS C 852
CSA C22.2 No 14
EN/IEC 60947-5-1
EN/IEC 60204-1
EN/ISO 13850
EN/IEC 60947-5-5
JIS C8201-5-1
EN/IEC 60947-1
JIS C8201-1
vibration resistance
+/- 3 mm (f= 2…500 Hz) conforming to IEC 60068-2-6
5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
protective treatment
TC