All categories
Compare Cart

XB6AD225B - Selector switch, Harmony XB6, black round, 16mm, 2 positions, stay put, 1NO + 1NC - Schneider Electric

Expected in 2-4 weeks
XB6AD225B - Selector switch, Harmony XB6, black round, 16mm, 2 positions, stay put, 1NO + 1NC - Schneider Electric - Selector switch, Harmony XB6, black round, 16mm, 2 positions, stay put, 1NO + 1NC - Schneider Electric - 0
XB6AD225B - Selector switch, Harmony XB6, black round, 16mm, 2 positions, stay put, 1NO + 1NC - Schneider Electric
16,08 €
16,08 € incl. VAT
Text About:
Selector switch, Harmony XB6, black round, 16mm, 2 positions, stay put, 1NO + 1NC - Schneider Electric
16,08 €
SPECIFICATIONS
Main
Device short name XB6
[ui] rated insulation voltage 250 V (pollution degree 3) conforming to EN/IEC 60947-1
Complementary
[ie] rated operational current 3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1
0.1 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1
0.22 A at 125 V, DC-13, R300 conforming to EN/IEC 60947-5-1
Product certifications CCC
CSA
GOST
UL
Handle front plate colour 18 mm
mounting diameter 16 mm
Product or component type Complete selector switch
[uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1
nema degree of protection NEMA 13 conforming to UL 50
NEMA 4 conforming to UL 50
NEMA 4X conforming to UL 50
NEMA 13 conforming to CSA C22.2 No 94
NEMA 4 conforming to CSA C22.2 No 94
NEMA 4X conforming to CSA C22.2 No 94
Connections - terminals Faston connectors, connection size: 2.8 x 0.5 mm
bezel material Plastic
Contacts material Silver alloy (Ag/Ni)
contact operation Slow-break
Contacts type and composition 1 NO
Electrical shock protection class Class II conforming to IEC 61140
Sale per indivisible quantity 1
width (w) 18 mm
electrical reliability Λ = 10exp(-8) at 5 V and 1 mA with confidence level of 90 % conforming to EN 60947-5-4
Type of operator stay put
Net weight 0.024 kg
Operating position Any position
depth 68 mm
mechanical durability 500000 cycles
electrical durability 1000000 cycles, AC-15 at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13 at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
Positive opening With conforming to EN/IEC 60947-5-1 appendix K
Shape of signaling unit head Square
Operator position information 2 positions 60°
Operator profile Black standard handle
Shock resistance 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Short-circuit protection 6 A cartridge fuse type gG
Terminals description iso n°1 (13-14)NON !@ !(21-22)NC
Environment
Ambient air temp for storage/transportation -40…70 °C
ip degree of protection IP65 conforming to IEC 60529
Range of product Harmony XB6
ambient air temperature for operation -25…70 °C
standards EN/IEC 60947-5-5
JIS C8201-5-1
EN/IEC 60947-1
EN/IEC 60947-5-1
CSA C22.2 No 14
JIS C 852
UL 508
JIS C8201-1
vibration resistance +/- 3 mm (f= 2…500 Hz) conforming to IEC 60068-2-6
5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6
protective treatment TC
Recently viewed
16,08 €
16,08 € incl. VAT
Expected in 2-4 weeks