Complementary
[ie] rated operational current
1.5 A at 240 V, AC-15, B300 conforming to EN/IEC 60947-5-1
3 A at 120 V, AC-15, B300 conforming to EN/IEC 60947-5-1
0.11 A at 250 V, DC-13, R300 conforming to EN/IEC 60947-5-1
0.22 A at 125 V, DC-13, R300 conforming to EN/IEC 60947-5-1
[ith] conventional thermal current
6 A conforming to EN/IEC 60947-5-1
Product certifications
BV
LROS (Lloyds register of shipping)
DNV
CE
CCC
CB Scheme
EAC
UKCA
Product or component type
Complete control station
tightening torque
0.8…1.2 N.m conforming to EN/IEC 60947-1
[uimp] rated impulse withstand voltage
4 kV conforming to EN/IEC 60947-1
Colour of base of enclosure
Light grey (RAL 7035)
cable entry
1 knock-out for cable entry 0…14 mm
2 knock-outs for Pg 13.5 cable gland and ISO M20
Connections - terminals
Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, >= 1 x 0.34 mm² without cable end conforming to EN/IEC 60947-1
Contacts material
Silver alloy (Ag/Ni)
contact operation
Slow-break
Operating travel
1.5 mm (NC changing electrical state)
4.3 mm (total travel)
Material
Polycarbonate
Colour of cover
Yellow (RAL 1021)
Control station application
Emergency switching off function
Emergency stop function
electrical reliability
Λ < 10exp(-6) at 5 V, 1 mA conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V, 3.4 mA conforming to EN/IEC 60947-5-4
Ik degree of protection
IK03 conforming to IEC 60068-2-75
Contacts usage
Monitoring contact
Control station composition
1 mushroom head Ø 40 mm push-button, red 1 NC unmarked marking
Net weight
0.144 kg
mechanical durability
300000 cycles
electrical durability
300000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
300000 cycles, AC-15, 3 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
300000 cycles, AC-15, 3 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
300000 cycles, DC-13, 0.3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
300000 cycles, DC-13, 1 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
Device presentation
Complete product
Positive opening
With conforming to EN/IEC 60947-5-1 appendix K
Operating force
47 N
Operator profile
1 mushroom head push-button
Operators description
Red unmarked 1 NC
Product destination
For XB5 Ø 22 mm control and signalling units
Shock resistance
30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
25 gn (duration = 6 ms) for 1000 shocks on each axis conforming to IEC 60068-2-27
Shape of screw head
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
Short-circuit protection
6 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP66 conforming to IEC 60529
IP67 conforming to IEC 60529
IP69 conforming to IEC 60529
IP69K conforming to ISO 20653
Range of product
Harmony XALK
ambient air temperature for operation
-40…70 °C
overvoltage category
Class II conforming to IEC 60536
standards
EN/IEC 60947-1
EN/IEC 60947-5-1
EN/IEC 60947-5-5
EN/IEC 60204-1
IEC 60947-5-4
IEC 60364-5-53
EN/ISO 13850
JIS C8201-1
JIS C8201-5-1
GB/T 14048.5
BS EN 60947-5-1
GOST IEC 60947-5-1
vibration resistance
5 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
25 mm peak to peak (f= 2…10 Hz) conforming to IEC 60068-2-6
protective treatment
TH