All categories
Compare Cart

XALD363B - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 red pilot light, 1 green flush, 1 red flush push buttons Ш22 - Schneider Electric

Expected in 2-4 weeks
XALD363B - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 red pilot light, 1 green flush, 1 red flush push buttons Ш22 - Schneider Electric - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 red pilot light, 1 green flush, 1 red flush push buttons Ш22 - Schneider Electric - 0
XALD363B - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 red pilot light, 1 green flush, 1 red flush push buttons Ш22 - Schneider Electric - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 red pilot light, 1 green flush, 1 red flush push buttons Ш22 - Schneider Electric - 1
XALD363B - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 red pilot light, 1 green flush, 1 red flush push buttons Ш22 - Schneider Electric - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 red pilot light, 1 green flush, 1 red flush push buttons Ш22 - Schneider Electric - 2
XALD363B - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 red pilot light, 1 green flush, 1 red flush push buttons Ш22 - Schneider Electric - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 red pilot light, 1 green flush, 1 red flush push buttons Ш22 - Schneider Electric - 3
XALD363B - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 red pilot light, 1 green flush, 1 red flush push buttons Ш22 - Schneider Electric
51,66 € excl. VAT
63,03 € incl. VAT
Text About:
Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 red pilot light, 1 green flush, 1 red flush push buttons Ш22 - Schneider Electric
63,03 €
SPECIFICATIONS
Main
Device short name XALD
Marking location Marking on push-button
service life 100000 h at rated voltage and 25 °C
[ui] rated insulation voltage 600 V (pollution degree 3) conforming to EN/IEC 60947-1
Complementary
[ie] rated operational current 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
[ith] conventional thermal current 10 A conforming to EN/IEC 60947-5-1
Product or component type Complete control station
tightening torque 0.8…1.2 N.m conforming to EN/IEC 60947-1
[uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-1
[us] rated supply voltage 24 V AC/DC
Colour of base of enclosure Light grey (RAL 7035)
Current consumption 18 mA
nema degree of protection NEMA 13
NEMA 4X
cable entry 2 knock-outs for cable entry, clamping capacity: 14 mm
2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12 mm
Colour of marking White marking when green, red or black caps
Black marking when white caps
Connections - terminals Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN/IEC 60947-1
Contacts material Silver alloy (Ag/Ni)
contact operation Slow-break
Operating travel 1.5 mm (NC changing electrical state)
2.6 mm (NO changing electrical state)
4.3 mm (total travel)
Material Polycarbonate
Colour of cover Dark grey (RAL 7016)
Control station application Start-Stop function
electrical reliability Λ < 10exp(-6) at 5 V, 1 mA conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V, 5 mA conforming to EN/IEC 60947-5-4
Signalling type Steady
supply voltage limits 19.2…30 V DC
21.6…26.4 V AC
Ik degree of protection IK05 conforming to EN 50102
Control station composition 1 flush push-button, green 1 NO I marking
1 flush push-button, red 1 NC O marking
1 pilot light
Net weight 0.261 kg
mechanical durability 10000000 cycles
electrical durability 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
Positive opening With conforming to EN/IEC 60947-5-1 appendix K
Light source colour Red
Resistance to high pressure washer 7000000 Pa at 55 °C, distance : 0.1 m
Operating force 3.5 N NC changing electrical state
3.8 N NO changing electrical state
Operator profile 2 flush push-buttons - 1 central pilot light
light source Integrated and protected LED
Operators description Green ''I'' 1 NO - red ''O'' 1 NC
Product destination For XB5 Ø 22 mm control and signalling units
Resistance to electrostatic discharge 6 kV on contact (on metal parts) conforming to IEC 61000-4-2
8 kV in free air (in insulating parts) conforming to IEC 61000-4-2
Shock resistance 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Shape of screw head Cross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
Resistance to electromagnetic fields 10 V/m conforming to IEC 61000-4-3
Surge withstand 1 kV conforming to IEC 61000-4-5
Short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
Environment
Ambient air temp for storage/transportation -40…70 °C
ip degree of protection IP66 conforming to IEC 60529
IP67
IP69
IP69K
Range of product Harmony XALD
ambient air temperature for operation -40…70 °C
overvoltage category Class II conforming to IEC 60536
standards EN/IEC 60947-5-4
CSA C22.2 No 14
UL 508
EN/IEC 60947-5-1
EN/IEC 60947-5-5
JIS C8201-5-1
EN/IEC 60947-1
JIS C8201-1
electromagnetic emission Class B conforming to IEC 55011
vibration resistance 5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6
protective treatment TH
resistance to fast transients 2 kV conforming to IEC 61000-4-4