All categories
Compare Cart

XALD103 - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 green flush push button Ш22, spring return, marked START, 1 NO - Schneider Electric

Expected in 2-4 weeks
XALD103 - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 green flush push button Ш22, spring return, marked START, 1 NO - Schneider Electric - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 green flush push button Ш22, spring return, marked START, 1 NO - Schneider Electric - 0
XALD103 - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 green flush push button Ш22, spring return, marked START, 1 NO - Schneider Electric - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 green flush push button Ш22, spring return, marked START, 1 NO - Schneider Electric - 1
XALD103 - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 green flush push button Ш22, spring return, marked START, 1 NO - Schneider Electric - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 green flush push button Ш22, spring return, marked START, 1 NO - Schneider Electric - 2
XALD103 - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 green flush push button Ш22, spring return, marked START, 1 NO - Schneider Electric - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 green flush push button Ш22, spring return, marked START, 1 NO - Schneider Electric - 3
XALD103 - Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 green flush push button Ш22, spring return, marked START, 1 NO - Schneider Electric
21,48 € excl. VAT
26,21 € incl. VAT
Text About:
Harmony XALD, XALK, Control station, plastic, dark grey lid, 1 green flush push button Ш22, spring return, marked START, 1 NO - Schneider Electric
26,21 €
SPECIFICATIONS
Main
Device short name XALD
Marking location Marking on push-button
[ui] rated insulation voltage 600 V (pollution degree 3) conforming to EN/IEC 60947-1
Complementary
[ie] rated operational current 6 A at 120 V, AC-15, A600 conforming to EN/IEC 60947-5-1
3 A at 240 V, AC-15, A600 conforming to EN/IEC 60947-5-1
1.2 A at 600 V, AC-15, A600 conforming to EN/IEC 60947-5-1
0.55 A at 125 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.27 A at 250 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
0.1 A at 600 V, DC-13, Q600 conforming to EN/IEC 60947-5-1
[ith] conventional thermal current 10 A conforming to EN/IEC 60947-5-1
Product or component type Complete control station
tightening torque 0.8…1.2 N.m conforming to EN/IEC 60947-1
[uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 60947-1
Colour of base of enclosure Light grey (RAL 7035)
nema degree of protection NEMA 13
NEMA 4X
cable entry 1 knock-out for cable entry, clamping capacity: 14 mm
2 knock-outs for Pg 13 cable gland and ISO M20, clamping capacity: 12 mm
Colour of marking White marking when green, red or black caps
Black marking when white caps
Connections - terminals Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to EN/IEC 60947-1
Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to EN/IEC 60947-1
Contacts material Silver alloy (Ag/Ni)
contact operation Slow-break
Operating travel 2.6 mm (NO changing electrical state)
4.3 mm (total travel)
Material Polycarbonate
Colour of cover Dark grey (RAL 7016)
Control station application Start function
electrical reliability Λ < 10exp(-6) at 5 V and 1 mA conforming to EN/IEC 60947-5-4
Λ < 10exp(-8) at 17 V and 5 mA conforming to EN/IEC 60947-5-4
Ik degree of protection IK03 conforming to EN 50102
Control station composition 1 flush push-button, green 1 NO START marking
Net weight 0.156 kg
mechanical durability 10000000 cycles
electrical durability 1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to EN/IEC 60947-5-1 appendix C
Positive opening Without
Resistance to high pressure washer 7000000 Pa at 55 °C, distance : 0.1 m
Operating force 3.8 N NO changing electrical state
Operator profile 1 flush push-button
Operators description Green ''START'' 1 NO
Product destination For XB5 Ø 22 mm control and signalling units
Shock resistance 30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27
50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27
Shape of screw head Cross compatible with Philips no 1 screwdriver
Cross compatible with pozidriv No 1 screwdriver
Slotted compatible with flat Ø 4 mm screwdriver
Slotted compatible with flat Ø 5.5 mm screwdriver
Short-circuit protection 10 A cartridge fuse type gG conforming to EN/IEC 60947-5-1
Environment
Ambient air temp for storage/transportation -40…70 °C
ip degree of protection IP66 conforming to IEC 60529
IP67
IP69
IP69K
Range of product Harmony XALD
ambient air temperature for operation -40…70 °C
overvoltage category Class II conforming to IEC 60536
standards EN/IEC 60947-5-4
CSA C22.2 No 14
EN/IEC 60947-5-1
UL 508
EN/IEC 60947-1
JIS C8201-5-1
EN/IEC 60947-5-5
JIS C8201-1
vibration resistance 5 gn (f= 12…500 Hz) conforming to IEC 60068-2-6
protective treatment TH