Complementary
product compatibility
XEDS2231 for reversing operation
XENT1991 for emergency stop
Control type
Intuitive
Control station colour
Yellow
Enclosure type
Complete ready for use
Product or component type
Pendant control station
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
4 kV emergency stop contact
Control station type
Double insulated
cable entry
Rubber sleeve with stepped entry 7…18 mm
Connections - terminals
Screw clamp terminals, 1 x 2.5 mm² with or without cable end
Screw clamp terminals, 2 x 1.5 mm² with or without cable end
Enclosure material
Polypropylene
contact operation
Snap action
rated operational power in w
1100 W AC-3 at 400 V conforming to IEC 60947-3 appendix A
1100 W AC-4 at 400 V conforming to IEC 60947-3 appendix A
3000 W AC-23B at 400 V
Control station application
Control of 2-speed hoist motor
Electrical circuit type
Power circuit
Ik degree of protection
IK08 conforming to EN 50102
Control station composition
1 2-directional button + 1 emergency stop
Net weight
0.42 kg
mechanical durability
3000000 cycles
electrical durability
1000000 cycles AC-3, 1100 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
1000000 cycles AC-4, 1100 W at 400 V, operating rate <10 cyc/mn, load factor = 0.4 conforming to IEC 60947-3 appendix A
Mechanical interlocking
With mechanical interlocking
control button type
Emergency stop push-button Ø 30 mm 3 NC trigger action
First direction button 2-pole raise, slow-fast
Second direction button 2-pole lower, slow-fast
Operating force
31 N
motor starter type
Reversing
Shock resistance
70 gn conforming to IEC 60068-2-27
Terminal identifier
(13-14)NON !@ !(11-12)NC
Terminals description iso n°2
(31-32)NC
(11-12)NC
(21-22)NC
Short-circuit protection
6 A fuse protection by cartridge fuse type aM
Terminals description iso n°1
(1-2)P
(11-12)P
(9-10)P
(7-8)P
(R1-R2)RP
(3-4) P
(R3-R4)RP
(5-6)P
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP65 conforming to IEC 60529
Range of product
Harmony XAC
ambient air temperature for operation
-25…70 °C
overvoltage category
Class II conforming to IEC 61140
standards
EN/IEC 60204-32
UL 508
EN/IEC 60947-5-1
EN/ISO 13850: 2006
CSA C22.2 No 14
EN/IEC 60947-5-5
vibration resistance
15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TH