Complementary
product compatibility
ZB2BE102 for emergency stop
XENG1191 for raise/lower direction
ZB2BE101 for right/left direction
Product certifications
GOST
CCC
Control station colour
Yellow
Enclosure type
Complete ready for use
Product or component type
Pendant control station
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
Control station type
Double insulated
cable entry
Rubber sleeve with stepped entry 8…26 mm
Connections - terminals
Screw clamp terminals, 1 x 0.5...1 x 2.5 mm² without cable end
Screw clamp terminals, 1 x 0.5...2 x 1.5 mm² with cable end
Enclosure material
Polypropylene
contact operation
Staggered
Slow-break
rated operational power in w
40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Control station application
Control of 2-speed hoist motor
Electrical circuit type
Control circuit
Ik degree of protection
IK08 conforming to EN 50102
contact code designation
A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A
A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A
Control station composition
4 push-buttons + 1 emergency stop
Net weight
0.7 kg
mechanical durability
1000000 cycles
Maximum resistance across terminals
25 MOhm
Mechanical interlocking
With mechanical interlocking between pairs
control button type
First push-button 1 NC + 2 NO raise, slow-fast
Second push-button 1 NC + 2 NO lower, slow-fast
Fourth push-button 1 NO left, slow
Third push-button 1 NO right, slow
Stop push-button Ø 40 mm 1 NC latching
Operating force
10 N third and fourth push-button
18 N first and second push-button
8 N emergency stop
Shock resistance
100 gn conforming to IEC 60068-2-27
Terminal identifier
(11-12)NC
(13-14)NON
Terminals description iso n°2
(13-14)NON
Terminals description iso n°3
(11-12)NC
Short-circuit protection
10 A fuse protection by cartridge fuse type gG
Terminals description iso n°1
(21-22)NC
(33-34)NON_CL
(13-14)NON
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP65 conforming to IEC 60529
Range of product
Harmony XAC
ambient air temperature for operation
-25…70 °C
overvoltage category
Class II conforming to IEC 61140
standards
EN/IEC 60947-5-1
UL 508
EN/IEC 60204-32
CSA C22.2 No 14
vibration resistance
15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TH