Complementary
product compatibility
ZB2BE101 for each direction
ZB2BE102 for emergency stop
Control type
Intuitive
Product certifications
CSA
UL
Control station colour
Yellow
Enclosure type
Complete ready for use
Product or component type
Pendant control station
[uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
Control station type
Double insulated
cable entry
Rubber sleeve with stepped entry 7…15 mm
Connections - terminals
Screw clamp terminals, 1 x 2.5 mm² with or without cable end
Screw clamp terminals, 2 x 1.5 mm² with or without cable end
Enclosure material
Polypropylene
contact operation
Slow-break
rated operational power in w
40 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
48 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
65 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Control station application
Control of single speed hoist motor
Electrical circuit type
Control circuit
Ik degree of protection
IK08 conforming to EN 50102
contact code designation
A600 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A
A600 AC-15, Ue = 600 V, Ie = 1.2 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
Q600 DC-13, Ue = 600 V, Ie = 0.1 A conforming to IEC 60947-5-1 appendix A
Control station composition
2 push-buttons + 1 emergency stop
Net weight
0.31 kg
mechanical durability
1000000 cycles
Maximum resistance across terminals
25 MOhm
Mechanical interlocking
With mechanical interlocking
control button type
First push-button 1 NO raise, slow
Second push-button 1 NO lower, slow
Stop push-button Ø 30 mm 1 NC latching
Operating force
13…15 N
Shock resistance
100 gn conforming to IEC 60068-2-27
Terminal identifier
(11-12)NC
(13-14)NON
Terminals description iso n°2
(11-12)NC
Short-circuit protection
10 A fuse protection by cartridge fuse type gG
Terminals description iso n°1
(13-14)NON
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP65 conforming to IEC 60529
Range of product
Harmony XAC
ambient air temperature for operation
-25…70 °C
overvoltage category
Class II conforming to IEC 61140
standards
CSA C22.2 No 14
EN/IEC 60947-5-1
EN/IEC 60204-32
UL 508
vibration resistance
15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
protective treatment
TH