Main
Minimum resistor value to associate
0.7 Ohm
Complementary
Activation threshold
785 V DC +/- 1 %
product compatibility
ATV61HC40N4
ATV61HC50N5
ATV61HC63N4
ATV61QC40N4
ATV61QC50N4
ATV61QC63N4
ATV71HC31N4
ATV71HC40N4
ATV71HC50N4
ATV71QC31N4
ATV71QC40N4
ATV71QC50N4
range compatibility
Altivar 71
Altivar 61Q
Altivar 71Q
Altivar 61
Load factor
0.05 for 750 kW at constant power and at engage threshold
0.15 for 550 kW at constant power and at engage threshold
0.5 for 440 kW at constant power and at engage threshold
thermal losses
750 W
Maximum braking power
750 kW
Permanent braking power
400 kW at 400 V (at constant power and at engage threshold)
Maximum dc bus voltage
850 V
Net weight
80 kg
Operating position
Vertical
Pollution degree
2 conforming to EN 50178
Protection type
Integrated thermal protection by thermal probe
Volume of cooling air
600 m3/h
Environment
Ambient air temp for storage/transportation
-25…70 °C
ip degree of protection
IP20
operating altitude
2000 m
ambient air temperature for operation
-10…50 °C
vibration resistance
0.2 gn