SPECIFICATIONS
Main
Number of phases Three phase
Value of inductance 1 mH
Complementary
electrical insulation class Class F
product compatibility Variable speed drive ATV310 motor: 7.5 kW - motor choke - 1 per drive
ATV31CD11N4 - line choke - 1 per drive
Variable speed drive ATV320 motor: 15 kW 525...600 V - three phase - motor choke - 1 per drive
ATV312HU55M3 - line choke - 1 per drive
LXM32.D30N4 - line choke - 1 per drive
ATV71HD18Y - line choke - 1 per drive
ATV312HD15S6 - motor choke - 1 per drive
ATV312HD11S6 - motor choke - 1 per drive
ATV312HD15N4 - line choke - 1 per drive
ATV61WD11N4C - line choke - 1 per drive
ATV61HD15N4 - line choke - 1 per drive
ATV71WD15N4 - line choke - 1 per drive
Variable speed drive ATV340 motor: 7.5 kW 380...480 V - line choke - 1 per drive
Variable speed drive ATV930 motor: 18.5 kW 500...690 V - three phase - line choke - 1 per drive
LXM32MC10N4 - line choke - 1 per drive
ATV312HD11N4 - motor choke - 1 per drive
Variable speed drive ATV320 motor: 5.5 kW 200...240 V - three phase - line choke - 1 per drive
Variable speed drive ATV320 motor: 7.5 kW 380...500 V - three phase - motor choke - 1 per drive
Variable speed drive ATV310 motor: 11 kW - line choke - 1 per drive
ATV312HU40M3 - line choke - 1 per drive
Variable speed drive ATV320 motor: 5.5 kW 200...240 V - three phase - motor choke - 1 per drive
ATV312HU40M3 - motor choke - 1 per drive
ATV61HD22Y - line choke - 1 per drive
Variable speed drive ATV340 motor: 11 kW 380...480 V - line choke - 1 per drive
ATV32HD11N4 - motor choke - 1 per drive
Variable speed drive ATV930 motor: 600 V - three phase - line choke - 25 hp - 1 per drive
LXM32.D18N4 - line choke - 1 per drive
Variable speed drive ATV320 motor: 15 kW 380...500 V - three phase - line choke - 1 per drive
ATV61HU55M3 - line choke - 1 per drive
ATV32HD11N4 - line choke - 1 per drive
ATV12PU40M3 - motor choke - 1 per drive
Variable speed drive ATV340 motor: 15 kW 380...480 V - line choke - 1 per drive
LXM32.D72N4 - line choke - 1 per drive
ATV312HU75N4 - motor choke - 1 per drive
Variable speed drive ATV320 motor: 11 kW 380...500 V - three phase - line choke - 1 per drive
ATV61WD11N4 - line choke - 1 per drive
ATV61HD11N4 - line choke - 1 per drive
ATV71WD11N4 - line choke - 1 per drive
ATV31CU75N4 - motor choke - 1 per drive
Variable speed drive ATV630 motor: 600 V - three phase - line choke - 30 hp - 1 per drive
Variable speed drive ATV320 motor: 4 kW 200...240 V - three phase - motor choke - 1 per drive
ATV312HU75M3 - line choke - 1 per drive
ATV61WD15N4 - line choke - 1 per drive
Variable speed drive ATV320 motor: 15 kW 525...600 V - three phase - line choke - 1 per drive
Variable speed drive ATV630 motor: 600 V - three phase - line choke - 25 hp - 1 per drive
ATV31CD15N4 - line choke - 1 per drive
ATV71PD11N4Z - line choke - 1 per drive
ATV312HD11N4 - line choke - 1 per drive
Variable speed drive ATV320 motor: 11 kW 380...500 V - three phase - motor choke - 1 per drive
ATV312HD15S6 - line choke - 1 per drive
Variable speed drive ATV320 motor: 7.5 kW 200...240 V - three phase - line choke - 1 per drive
ATV61HD18Y - line choke - 1 per drive
Variable speed drive ATV630 motor: 18.5 kW 500...690 V - three phase - line choke - 1 per drive
ATV32HD15N4 - line choke - 1 per drive
ATV71HU40M3 - line choke - 1 per drive
Variable speed drive ATV310 motor: 7.5 kW - line choke - 1 per drive
Variable speed drive ATV930 motor: 600 V - three phase - line choke - 30 hp - 1 per drive
Variable speed drive ATV320 motor: 4 kW 200...240 V - three phase - line choke - 1 per drive
ATV312HU55M3 - motor choke - 1 per drive
Variable speed drive ATV320 motor: 7.5 kW 200...240 V - three phase - motor choke - 1 per drive
ATV312HU75M3 - motor choke - 1 per drive
ATV61HU40M3 - line choke - 1 per drive
Variable speed drive ATV930 motor: 22 kW 500...690 V - three phase - line choke - 1 per drive
ATV32HU75N4 - motor choke - 1 per drive
Variable speed drive ATV310 motor: 11 kW - motor choke - 1 per drive
LXM32MD85N4 - line choke - 1 per drive
ATV71HD11N4 - line choke - 1 per drive
Variable speed drive ATV320 motor: 11 kW 525...600 V - three phase - line choke - 1 per drive
ATV71HD22Y - line choke - 1 per drive
ATV31CD11N4 - motor choke - 1 per drive
ATV71HD15N4 - line choke - 1 per drive
Variable speed drive ATV630 motor: 22 kW 500...690 V - three phase - line choke - 1 per drive
ATV71HU55M3 - line choke - 1 per drive
ATV12HU40M3 - motor choke - 1 per drive
Variable speed drive ATV320 motor: 11 kW 525...600 V - three phase - motor choke - 1 per drive
ATV61WD15N4C - line choke - 1 per drive
[in] rated current 31 A
range compatibility Lexium 32
Altivar 312 Solar
Easy Altivar 310
Altivar 12
Lexium 62
Altivar 71
Altivar Machine ATV340
Altivar Machine ATV320
Altivar Process ATV900
Altivar 31C
Altivar 61
Lexium 52
Altivar 32
Altivar 312
Altivar Process ATV600
Easy Altivar 310L
Handle front plate colour 170 mm
Product or component type Line/motor choke
thermal losses 90 W
Device application Reduction of current harmonics
Reduction of overvoltages at motor terminals
Max current 1.65 x nominal current (duration = 60 s)
width (w) 155 mm
Leakage distance 11.5 mm conforming to IEC 60664
Net weight 6 kg
Minimum clearance distance 5.5 mm IEC 60664
Maximum voltage drop at rated load 5 %
depth 135 mm
Pollution degree 2 conforming to EN 50178
electrical connection Terminal 16 mm² / AWG 4, 1.2…1.4 N.m
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Power supply frequency 50...60 Hz
Environment
Ambient air temp for storage/transportation -25…70 °C
ip degree of protection Choke: IP00
Terminals: IP10
operating altitude <= 1000 m without current derating
1000...3000 m with current derating 1 % per 100 m
Range of product Altivar
ambient air temperature for operation 45…55 °C (with current derating of 2 % per °C)
0…45 °C (without current derating)
Environmental characteristics 3B1 conforming to IEC 721-3-3
3C2 conforming to IEC 721-3-3
3S1 conforming to IEC 721-3-3
standards EN 50178
IEC 60076 (with HD398)
VDE 0160 level 1
relative humidity 0…95 %
vibration resistance 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6