Main
Number of phases
Three phase
Value of inductance
10 mH
Complementary
electrical insulation class
Class F
product compatibility
ATV12H018F1 - motor choke - 1 per drive
ATV12H018M2 - motor choke - 1 per drive
ATV12H018M3 - motor choke - 1 per drive
ATV12H037F1 - motor choke - 1 per drive
ATV12H037M2 - motor choke - 1 per drive
ATV12H037M3 - motor choke - 1 per drive
ATV12H055M2 - motor choke - 1 per drive
ATV12P037F1 - motor choke - 1 per drive
ATV12P037M2 - motor choke - 1 per drive
ATV12P037M3 - motor choke - 1 per drive
ATV12P055M2 - motor choke - 1 per drive
ATV312H018M3 - line choke - 1 per drive
ATV312H037M3 - line choke - 1 per drive
ATV312H037N4 - line choke - 1 per drive
ATV312H055M3 - line choke - 1 per drive
ATV312H055N4 - line choke - 1 per drive
ATV312H075M3 - line choke - 1 per drive
ATV312H075N4 - line choke - 1 per drive
ATV312H075S6 - line choke - 1 per drive
ATV312HU11N4 - line choke - 1 per drive
ATV312HU15N4 - line choke - 1 per drive
ATV312HU15S6 - line choke - 1 per drive
ATV32H037N4 - line choke - 1 per drive
ATV32H055N4 - line choke - 1 per drive
ATV32H075N4 - line choke - 1 per drive
ATV32HU11N4 - line choke - 1 per drive
ATV32HU15N4 - line choke - 1 per drive
ATV61H075M3 - line choke - 1 per drive
ATV61H075N4 - line choke - 1 per drive
ATV61HU15N4 - line choke - 1 per drive
ATV61HU30Y - line choke - 1 per drive
ATV61W075N4 - line choke - 1 per drive
ATV61W075N4C - line choke - 1 per drive
ATV61WU15N4 - line choke - 1 per drive
ATV61WU15N4C - line choke - 1 per drive
ATV71H037M3 - line choke - 1 per drive
ATV71H075M3 - line choke - 1 per drive
ATV71H075N4 - line choke - 1 per drive
ATV71HU15N4 - line choke - 1 per drive
ATV71HU22Y - line choke - 1 per drive
ATV71HU30Y - line choke - 1 per drive
ATV71P075N4Z - line choke - 1 per drive
ATV71PU15N4Z - line choke - 1 per drive
ATV71W075N4 - line choke - 1 per drive
ATV71WU15N4 - line choke - 1 per drive
ATV61HU22S6X - line choke - 1 per drive
ATV71HU15S6X - line choke - 1 per drive
ATV71HU22S6X - line choke - 1 per drive
ATV31C037N4 - line choke - 1 per drive
ATV31C055N4 - line choke - 1 per drive
ATV31C075N4 - line choke - 1 per drive
ATV31CU11N4 - line choke - 1 per drive
ATV31CU15N4 - line choke - 1 per drive
Variable speed drive ATV310 motor: 0.37 kW - line choke - 1 per drive
Variable speed drive ATV310 motor: 0.75 kW - line choke - 1 per drive
Variable speed drive ATV340 motor: 0.75 kW 380...480 V - line choke - 1 per drive
Variable speed drive ATV340 motor: 1.5 kW 380...480 V - line choke - 1 per drive
Variable speed drive ATV320 motor: 0.37 kW 380...500 V - three phase - line choke - 1 per drive
Variable speed drive ATV320 motor: 0.55 kW 380...500 V - three phase - line choke - 1 per drive
Variable speed drive ATV320 motor: 0.75 kW 380...500 V - three phase - line choke - 1 per drive
Variable speed drive ATV320 motor: 1.1 kW 380...500 V - three phase - line choke - 1 per drive
Variable speed drive ATV320 motor: 1.5 kW 380...500 V - three phase - line choke - 1 per drive
Variable speed drive ATV320 motor: 0.18 kW 200...240 V - three phase - line choke - 1 per drive
Variable speed drive ATV320 motor: 0.37 kW 200...240 V - three phase - line choke - 1 per drive
Variable speed drive ATV320 motor: 0.55 kW 200...240 V - three phase - line choke - 1 per drive
Variable speed drive ATV320 motor: 0.75 kW 200...240 V - three phase - line choke - 1 per drive
Variable speed drive ATV320 motor: 0.75 kW 525...600 V - three phase - line choke - 1 per drive
Variable speed drive ATV320 motor: 1.5 kW 525...600 V - three phase - line choke - 1 per drive
Variable speed drive ATV320 motor: 2.2 kW 525...600 V - three phase - line choke - 1 per drive
Variable speed drive ATV630 motor: 2.2 kW 500...690 V - three phase - line choke - 1 per drive
Variable speed drive ATV630 motor: 3 kW 500...690 V - three phase - line choke - 1 per drive
Variable speed drive ATV630 motor: 4 kW 500...690 V - three phase - line choke - 1 per drive
Variable speed drive ATV930 motor: 2.2 kW 500...690 V - three phase - line choke - 1 per drive
Variable speed drive ATV930 motor: 3 kW 500...690 V - three phase - line choke - 1 per drive
Variable speed drive ATV930 motor: 4 kW 500...690 V - three phase - line choke - 1 per drive
Variable speed drive ATV630 motor: 600 V - three phase - line choke - 3 hp - 1 per drive
Variable speed drive ATV930 motor: 600 V - three phase - line choke - 3 hp - 1 per drive
Variable speed drive ATV310L motor: 0.75 kW
Variable speed drive ATV310L motor: 1.5 kW
Variable speed drive ATV310L motor: 2.2 kW
Variable speed drive ATV310L motor: 3.0 kW
Variable speed drive ATV310L motor: 4.0 kW
Variable speed drive ATV310L motor: 5.5 kW
[in] rated current
4 A
range compatibility
Altivar 61
Altivar 312
Altivar Process ATV900
Altivar 32
Altivar 312 Solar
Altivar Process ATV600
Altivar 31C
Lexium 62
Easy Altivar 310
Altivar Machine ATV340
Altivar Machine ATV320
Altivar 71
Altivar 12
Easy Altivar 310L
Handle front plate colour
135 mm
Product or component type
Line/motor choke
thermal losses
45 W
Device application
Reduction of current harmonics
Max current
1.65 x nominal current (duration = 60 s)
width (w)
100 mm
Leakage distance
11.5 mm conforming to IEC 60664
Net weight
1.5 kg
Minimum clearance distance
5.5 mm IEC 60664
Maximum voltage drop at rated load
5 %
depth
60 mm
Pollution degree
2 conforming to EN 50178
electrical connection
Terminal 2.5 mm² / AWG 12, 0.4…0.6 N.m
Shock resistance
15 gn for 11 ms conforming to IEC 60068-2-27
Power supply frequency
50...60 Hz
Environment
Ambient air temp for storage/transportation
-25…70 °C
ip degree of protection
Choke: IP00
Terminals: IP20
operating altitude
<= 1000 m without current derating
1000...3000 m with current derating 1 % per 100 m
Range of product
Altivar
ambient air temperature for operation
45…55 °C (with current derating of 2 % per °C)
0…45 °C (without current derating)
Environmental characteristics
3B1 conforming to IEC 721-3-3
3C2 conforming to IEC 721-3-3
3S1 conforming to IEC 721-3-3
standards
VDE 0160 level 1
IEC 60076 (with HD398)
EN 50178
relative humidity
0…95 %
vibration resistance
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6