SPECIFICATIONS
Main
Device short name V
[ithe] thermal current under enclosure 140 A
Range TeSys
Product Name TeSys VARIO
Product type Switch body
degree of protection IP20 conforming to IEC 60529
performance level High performance
Complementary
[icm] rated short circuit making capacity 2.8 kA at 400 V at Ipeak
[ie] rated operational current 83 A AC-23 Ue: 400 V
[ue] rated operational voltage 690 V AC 50/60 Hz
[ics] rated service breaking capacity 1400 A at 400 V (AC-21A)
1400 A at 400 V (AC-22A)
1400 A at 400 V (AC-23A)
[icw] rated short-time withstand rms current 2100 A at 400 V duration: 1 s
[ith] conventional thermal current 175 A
intermittent duty class 30
Product certifications UL
CSA
GL
UKCA
Handle front plate colour 125 mm
tightening torque Power circuit: 22.6 N.m - on screw clamp terminals
[uimp] rated impulse withstand voltage 8 kV
product weight 0.9 kg
width (w) 90 mm
mechanical robustness Vibrations 10...150 Hz (1 gn) conforming to IEC 60068-2-6
Shocks 11 ms (30 Gn) conforming to IEC 60068-2-27
network frequency 50/60 Hz
Iec rated operational power in w 30 kW at 230...240 V (AC-3)
37 kW at 400...415 V (AC-3)
37 kW at 690 V (AC-3)
45 kW at 500 V (AC-3)
45 kW at 690 V (AC-23A)
55 kW at 500 V (AC-23A)
30 kW at 230...240 V (AC-23A)
45 kW at 400...415 V (AC-23A)
Iec terminal connection Power circuit: screw clamp terminals70 mm² - flexible - with cable end
Power circuit: screw clamp terminals95 mm² - solid
Mounting support Symmetrical rail
Plate
depth 90 mm
mechanical durability 30000 cycles
electrical durability 30000 cycles AC-21
30000 cycles DC-1...5
Network type AC
DC
Making capacity ( i rms) 1750 A at 400 V AC-22A
1750 A at 400 V AC-23A
1600 A at 400 V AC-21A
Rated conditional short circuit current 10 kA at 400 V - associated fuse 200 A aM
10 kA at 400 V - associated fuse 200 A gG
contact type and composition 3 NO
Suitability for isolation Yes
Poles description 3P
Environment
ambient air temperature for operation -20…50 °C
standards IEC 60947-3
fire resistance 960 °C conforming to IEC 60695-2-1
protective treatment TC