Complementary
product compatibility
PacDrive LMC Pro 2
PacDrive LMC Eco
PacDrive LMC Pro
range compatibility
PacDrive LMC motion controller
Product certifications
CSA
cULus
GOST-R
C-Tick
response time
<= 10 ms from state 0 to state 1 for output
<= 10 ms from state 1 to state 0 for output
Product or component type
Discrete output module
Current consumption
160 mA at 5 V DC bus
current per channel
5 A
marking
CE
Discrete output function
4 NO
maximum power dissipation in w
2.3 W
output voltage
230 V AC
30 V DC
isolation
No insulation between channels
500 Vrms AC insulation between channel and bus
Maximum current per output common
10 A
Colour
Black
Net weight
0.025 kg
Discrete output type
Relay
Discrete output number
4
mechanical durability
20000000 cycles
electrical durability
500000 cycles at 5 A
output voltage limits
184...276 V AC
24...36 V DC
Pollution degree
2 conforming to IEC 60664
Shock resistance
15 gn for 11 ms
Protection type
Reverse polarity protection
Without short-circuit protection
Without overload protection
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP20 conforming to IEC 61131-2
operating altitude
0...2000 m
Range of product
Modicon TM5
ambient air temperature for operation
-10…55 °C without derating (horizontal installation)
-10…60 °C with derating factor (horizontal installation)
-10…50 °C (vertical installation)
electromagnetic compatibility
Electrostatic discharge immunity test, 4 kV on contact conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test, 8 kV in air conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields, 1 V/m 2...2.7 GHz conforming to EN/IEC 61000-4-3
Susceptibility to electromagnetic fields, 10 V/m 80...2000 MHz conforming to EN/IEC 61000-4-3
Electrical fast transient/burst immunity test, 1 kV I/O conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test, 1 kV shielded cable conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test, 2 kV power lines conforming to EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test, 0.5 kV differential mode conforming to EN/IEC 61000-4-5
1.2/50 µs shock waves immunity test, 1 kV common mode conforming to EN/IEC 61000-4-5
Conducted RF disturbances conforming to EN/IEC 61000-4-6
Conducted and radiated emissions conforming to CISPR 11
standards
CSA C22.2 No 213
UL 508
IEC 61131-2
CSA C22.2 No 142
Storage altitude
0…3000 m
relative humidity
5…95 % without condensation
vibration resistance
1 gn at 8.4…150 Hz on DIN rail
3.5 mm at 5…8.4 Hz on DIN rail