SPECIFICATIONS
Main
Device short name TM3SAF
Safety module application For emergency stop and switch monitoring
[uc] control circuit voltage 24 V DC
[ui] rated insulation voltage 300 V (pollution degree 2) conforming to IEC 60647-5-1
Complementary
[ics] rated service breaking capacity 4 A 24 V 50 ms DC-13 relay output
[ith] conventional thermal current 18 A
Product certifications EAC
CSA Haz Loc Class 1 Division 2 (pending)
RCM
TÜV
UL 61010-2-201
CSA 61010-2-201 (pending)
ANSI Haz Loc Class 1 Division 2 (pending)
Handle front plate colour 94 mm
Product or component type Safety module
[uimp] rated impulse withstand voltage 4 kV overvoltage category III conforming to IEC 60647-5-1
[us] rated supply voltage 24 V - 15...20 % DC
Current consumption 100 mA at 24 V DC external supply
Connections - terminals Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.5 mm² flexible without cable end other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.75 mm² solid without cable end other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 0.34 mm² flexible with cable end, without bezel other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.5 mm² flexible with cable end, with double bezel other terminals
Associated fuse rating 4 A gG or gL for relay output conforming to EN/IEC 60947-5-1
6 A fast blow for relay output conforming to EN/IEC 60947-5-1
marking CE
UL
EFUP 10
EAC
RCM
TÜV
CSA
minimum output current 10 mA for relay output
output thermal current 6 A per relay for relay output
Output type Relay instantaneous opening, 3 NO circuit(s), potential free
Function of module Emergency stop monitoring 1-channel wiring
Emergency stop monitoring 2-channel wiring
Monitoring of a movable guard with 2 switches and automatic start
safety reliability data DC = 95 % conforming to EN/ISO 13849-1
PFHd = 5E-9 1/h conforming to IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A
PFHd = 30E-9 1/h conforming to IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A
MTTFd = 500 years conforming to EN/ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A
MTTFd = 85 years conforming to EN/ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A
SFF = 95 % conforming to IEC 61508-1
HFT = 1 conforming to IEC 61508-1
Type = A conforming to IEC 61508-1
output voltage 10 V relay output
width (w) 43.7 mm
mechanical robustness Bumps 6 ms 300 shocks (25 gn) conforming to IEC 60068-2-27
Local signalling 8 LEDs (green/red) for user
Net weight 0.19 kg
Maximum cable distance between devices 30 m
Maximum response time on input open 40 ms
Mounting support Top hat type TH35-7.5 rail conforming to IEC 60715
Top hat type TH35-15 rail conforming to IEC 60715
wall mount using attached fasteners
depth 73 mm
Pollution degree 2
Power consumption in w 0.2 W at 5 V DC
3.6 W at 24 V DC
electrical connection Screw terminal
Maximum switching voltage 230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening)
24 V utilisation category DC-13 (relay instantaneous opening)
Number of safety circuits 3 NO for relay instantaneous opening
input protection type Internal, electronic
Synchronisation time between inputs Unlimited
Resistance to electrostatic discharge 8 kV in air conforming to EN/IEC 61000-4-2
6 kV on contact conforming to EN/IEC 61000-4-2
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Safety level Can reach PL e/category 4 conforming to EN/ISO 13849-1: 2008
Can reach PL e/category 4 conforming to EN/ISO 13849-2: 2012
Can reach SILCL 3 conforming to EN/IEC 62061: 2005
Can reach SIL 3 conforming to EN/IEC 61508: 2010
Resistance to electromagnetic fields 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
Surge withstand 1 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5 DC
1 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5 DC
Environment
Ambient air temp for storage/transportation -25…70 °C
ip degree of protection IP20 (terminals) conforming to EN/IEC 60529
operating altitude 0...2000 m
Range of product Modicon TM3 Safety
ambient air temperature for operation -10…55 °C horizontal installation
electromagnetic compatibility Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to EN/IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3
Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8
Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5
Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to EN 55011
Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to EN 55011
Resistance to conducted disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6
standards EN/IEC 60947-1
EN/IEC 60947-5-1
EN 60204-1
EN/ISO 13850
EN 1088/ISO 14119
Storage altitude 0…3000 m
relative humidity 10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
electromagnetic emission Radiated emissions - test level: 50 dBµV/m class A ( 24 V DC) at 30…230 Hz conforming to IEC 61131-3
Radiated emissions - test level: 57 dBµV/m class A ( 24 V DC) at 230…1000 Hz conforming to IEC 61131-3
vibration resistance +/- 3.5 mm (f= 5…150 Hz) conforming to IEC 60068-2-6
resistance to fast transients 3 kV for power lines (DC) (DC) conforming to EN/IEC 61000-4-4
2 kV for I/O lines conforming to EN/IEC 61000-4-4
resistance to magnetic fields 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
Q&A and product info

Contact Us

Professional sales of electrical equipment in Estonia, Latvia, Lithuania, and Finland. Certified low-voltage components, circuit breakers, contactors, and industrial automation solutions. Same-day quotations and fast delivery across the Baltics and Finland.

Baltelec
+372 5326 4976

Mon–Fri 9:00–17:00

info@baltelec.eu

Response within 2 hours

TM3SAF5R Schneider Electric is a professional Modicon M221 product designed for enterprises. BaltElec specializes in wholesale and product distribution in Estonia, Latvia, Lithuania, and Finland.

  • Authentic Schneider Electric product, certificates and compliance documents available.
  • Project pricing – request a quote for larger quantities (MOQ may apply).
  • Fast delivery across the Baltics and Finland; cooperation with trusted couriers.
  • Technical support and selection assistance based on your requirements.

Pricing: Request a special offer. The price depends on quantity, delivery, and payment terms.

Modicon M221 specifications may vary by model. For an exact match, please send us your requirements or check the technical data sheet.

FAQ for TM3SAF5R - Schneider Electric

Recently viewed
TM3SAF5R - Schneider Electric
Safety module, Modicon TM3 Safety, 1 Function, Cat 4 PL e/SIL CL3 (screw) 24 VDC
208,68 € excl. VAT
258,77 € incl. VAT
Pending restock