All categories
Compare Cart

TM241C24R - Logic controller, Modicon M241, 24 IO relay - Schneider Electric

Expected in 2-4 weeks
TM241C24R - Logic controller, Modicon M241, 24 IO relay - Schneider Electric - Logic controller, Modicon M241, 24 IO relay - Schneider Electric - 0
TM241C24R - Logic controller, Modicon M241, 24 IO relay - Schneider Electric
419,17 € excl. VAT
511,39 € incl. VAT
Text About:
Logic controller, Modicon M241, 24 IO relay - Schneider Electric
511,39 €
SPECIFICATIONS
Main
Discrete input voltage type DC
Discrete output logic Positive logic (source)
Discrete input current 5 mA for input
battery type BR2032 lithium non-rechargeable, battery life: 4 year(s)
Complementary
Accuracy +/- 0.1 % at 0.02…0.1 kHz for fast output
+/- 1 % at 0.1…1 kHz for fast output
Application structure 4 cyclic master tasks
3 cyclic master tasks + 1 freewheeling task
8 external event tasks
8 event tasks
data storage equipment <= 16 GB SD card (optional)
memory capacity 8 MB for program
64 MB for system memory RAM
Product certifications IACS E10
RCM
cULus
CSA
response time 50 µs turn-on, I0...I13 terminal(s) for input
control signal type A/B at 100 kHz for fast input (HSC mode)
Pulse/direction at 200 kHz for fast input (HSC mode)
Single phase at 200 kHz for fast input (HSC mode)
Handle front plate colour 90 mm
Product or component type Logic controller
[us] rated supply voltage 100...240 V AC
marking CE
reset time 10 ms automatic reset output
12 s automatic reset fast output
Configurable filtering time 1 µs for fast input
Data backed up 128 MB built-in flash memory for backup of user programs
Discrete i/o number 24
Discrete output current 2 A for relay output (Q4...Q9)
0.1 A for fast output (PTO mode) (TR0...TR3)
0.5 A for transistor output (TR0...TR3)
clock drift <= 60 s/month at 25 °C
Discrete input logic Sink or source
width (w) 150 mm
network frequency 50/60 Hz
supply voltage limits 85…264 V
Counting input number 4 fast input (HSC mode) at 200 kHz
14 standard input at 1 kHz
Discrete input voltage 24 V
Local signalling 1 LED (green) for PWR
1 LED (green) for RUN
1 LED (red) for module error (ERR)
1 LED (red) for I/O error (I/O)
1 LED (green) for SD card access (SD)
1 LED (red) for BAT
1 LED (green) for SL1
1 LED (green) for SL2
1 LED (red) for bus fault on TM4 (TM4)
1 LED per channel (green) for I/O state
Discrete input number 14, discrete input 8 fast input conforming to IEC 61131-2 Type 1
Net weight 0.53 kg
Realtime clock With
Discrete output type Transistor
Relay
Maximum cable distance between devices Unshielded cable: <50 m for input
Shielded cable: <10 m for fast input
Unshielded cable: <50 m for output
Shielded cable: <3 m for fast output
Discrete output voltage 5...125 V DC for relay output
5...250 V AC for relay output
24 V DC for transistor output
voltage state 1 guaranteed >= 15 V for input
communication port protocol Non isolated serial link: Modbus master/slave
Discrete output number 6 relay
4 transistor 4 fast output
Immunity to microbreaks 10 ms
input impedance 4.7 kOhm for input
Integrated connection type Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface
Non isolated serial link serial 2 with removable screw terminal block connector and RS485 interface
USB port with mini B USB 2.0 connector
Mounting support Top hat type TH35-15 rail conforming to IEC 60715
Top hat type TH35-7.5 rail conforming to IEC 60715
plate or panel with fixing kit
depth 95 mm
backup time 2 years at 25 °C
output voltage limits 125 V DC relay output
30 V DC transistor output
277 V AC relay output
voltage state 0 guaranteed <= 5 V for input
Pollution degree 2
electrical connection removable screw terminal blockfor inputs and outputs (pitch 5.08 mm)
removable screw terminal blockfor connecting the 24 V DC power supply (pitch 5.08 mm)
Maximum number of i/o expansion module 7 (local I/O-Architecture)
14 (remote I/O-Architecture)
maximum output frequency 1 kHz for transistor output
20 kHz for fast output (PWM mode)
100 kHz for fast output (PLS mode)
Insulation Between supply and internal logic at 500 V AC
Non-insulated between supply and ground
Sensor power supply 24 V DC at 400 mA supplied by the controller
Execution time for 1 kinstruction 0.3 ms for event and periodic task
0.7 ms for other instruction
Resistance to electrostatic discharge 8 kV in air conforming to EN/IEC 61000-4-2
4 kV on contact conforming to EN/IEC 61000-4-2
Shock resistance 15 gn for 11 ms
Resistance to electromagnetic fields 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
Surge withstand 2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5
2 kV relay output common mode conforming to EN/IEC 61000-4-5
1 kV shielded cable common mode conforming to EN/IEC 61000-4-5
1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5
1 kV relay output differential mode conforming to EN/IEC 61000-4-5
1 kV input common mode conforming to EN/IEC 61000-4-5
1 kV transistor output common mode conforming to EN/IEC 61000-4-5
Supply (serial 1)serial link supply: 5 V, <200 mA
Protection type Short-circuit protection for transistor output
Short-circuit and overload protection with automatic reset for transistor output
Reverse polarity protection for transistor output
Without protection for relay output
Transmission rate 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232
480 Mbit/s for bus length of 3 m for USB
Positioning functions PTO function 4 channel(s) (positioning frequency: 100 kHz)
Environment
Ambient air temp for storage/transportation -25…70 °C
ip degree of protection IP20 with protective cover in place
operating altitude 0...2000 m
Range of product Modicon M241
ambient air temperature for operation -10…50 °C (vertical installation)
-10…55 °C (horizontal installation)
Resistance to conducted disturbances 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6
3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL)
10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
standards ANSI/ISA 12-12-01
CSA C22.2 No 142
CSA C22.2 No 213
EN/IEC 61131-2:2007
Marine specification (LR, ABS, DNV, GL)
UL 1604
UL 508
Storage altitude 0…3000 m
relative humidity 10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
electromagnetic emission Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011
Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011
Conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines) at 0.15…0.5 MHz conforming to EN/IEC 55011
Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines) at 0.5…300 MHz conforming to EN/IEC 55011
Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011
Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011
Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 230…1000 MHz conforming to EN/IEC 55011
vibration resistance 3.5 mm at 5…8.4 Hz on symmetrical rail
3 gn at 8.4…150 Hz on symmetrical rail
3.5 mm at 5…8.4 Hz on panel mounting
3 gn at 8.4…150 Hz on panel mounting
resistance to fast transients 2 kV (power lines) conforming to EN/IEC 61000-4-4
2 kV (relay output) conforming to EN/IEC 61000-4-4
1 kV (serial link) conforming to EN/IEC 61000-4-4
1 kV (input) conforming to EN/IEC 61000-4-4
1 kV (transistor output) conforming to EN/IEC 61000-4-4