All categories
Compare Cart

SR3PACKBD - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 10 I/O, 24 V DC - Schneider Electric

Expected in 2-4 weeks
SR3PACKBD - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 10 I/O, 24 V DC - Schneider Electric - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 10 I/O, 24 V DC - Schneider Electric - 0
SR3PACKBD - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 10 I/O, 24 V DC - Schneider Electric
254,89 €
254,89 € incl. VAT
Text About:
Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 10 I/O, 24 V DC - Schneider Electric
254,89 €
SPECIFICATIONS
Main
Analogue input resolution 8 bits
Discrete input current 4 mA
Maximum permissible voltage 30 V for analogue input circuit
maximum supply current 100 mA (with extensions)
100 mA (without extension)
reverse polarity protection With
Complementary
Kit composition SR3B101BD
Cable PC SR2USB01 for connection to PC
local display With
Product certifications GL
UL
CSA
GOST
C-Tick
response time 10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay output
Analogue input range 0...24 V
0...10 V
Product or component type Modular discovery packs
tightening torque 0.5 N.m
[uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
[us] rated supply voltage 24 V
Connections - terminals Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid
Screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid
Screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end
current state 0 guaranteed <= 0.5 mA (IB...IG used as discrete input circuit)
<= 0.75 mA (I1...IA and IH...IR discrete input circuit)
output thermal current 8 A for all 4 outputs for relay output
Analogue input number 4
current state 1 guaranteed >= 1.2 mA (IB...IG used as discrete input circuit)
>= 2.2 mA (I1...IA and IH...IR discrete input circuit)
Operating distance 10 m between stations, with screened cable (sensor not isolated) for analogue input circuit
Analogue input type Common mode
Contacts type and composition NO for relay output
Clock With
clock drift 12 min/year at 0…55 °C
6 s/month at 25 °C
conversion error +/- 5 % at 25 °C for analogue input circuit
+/- 6.2 % at 55 °C for analogue input circuit
Discrete input type Resistive
number of outputs 4 relay
supply voltage limits 19.2…30 V
Discrete input voltage 24 V DC
Discrete input number 6 conforming to EN/IEC 61131-2 type 1
Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1
Net weight 0.7 kg
counting frequency 1 kHz for discrete input
voltage state 1 guaranteed >= 15 V for I1...IA and IH...IR discrete input circuit
>= 15 V for IB...IG used as discrete input circuit
Immunity to microbreaks 1 ms
input impedance 12 kOhm for IB...IG used as analogue input circuit
12 kOhm for IB...IG used as discrete input circuit
7.4 kOhm for I1...IA and IH...IR discrete input circuit
switching capacity in ma >= 10 mA at 12 V (relay output)
mechanical durability 10000000 cycles for relay output
power dissipation in w 3 W without extension
8 W with extensions
backup time 10 years at 25 °C
electrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
output voltage limits 24...250 V AC (relay output)
5...30 V DC (relay output)
repeat accuracy +/- 2 % at 55 °C for analogue input circuit
voltage state 0 guaranteed <= 5 V for I1...IA and IH...IR discrete input circuit
<= 5 V for IB...IG used as discrete input circuit
<= 5 V
Pollution degree 2 conforming to EN/IEC 61131-2
Maximum altitude transport 3048 m
Input/output number 10
Input compatibility 3-wire proximity sensors PNP for discrete input
Lsb value 39 mV for analogue input circuit
conversion time Smart relay cycle time for analogue input circuit
cycle time 6…90 ms
Number or control scheme lines 120 with ladder programming
0…200 with FBD programming
Operating rate in hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay output
Temperature probe type NTC 10k at 25 °C
NTC 1000k at 25 °C
KTY81 210/220/221/222/250
Pt 500
checks Program memory on each power up
Environment
Ambient air temp for storage/transportation -40…70 °C
ip degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529
operating altitude 2000 m
Range of product Zelio Logic
ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
Environmental characteristics EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2
overvoltage category III conforming to EN/IEC 60664-1
standards EN/IEC 60068-2-27 Ea
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-3
EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-11
EN/IEC 61000-4-5
EN/IEC 61000-4-2 level 3
EN/IEC 61000-4-12
EN/IEC 61000-4-4 level 3
relative humidity 95 % without condensation or dripping water
Recently viewed
254,89 €
254,89 € incl. VAT
Expected in 2-4 weeks