All categories
Compare Cart

SR3PACK2FU - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 26 I/O, 100...240 V AC - Schneider Electric

Expected in 2-4 weeks
SR3PACK2FU - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 26 I/O, 100...240 V AC - Schneider Electric - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 26 I/O, 100...240 V AC - Schneider Electric - 0
SR3PACK2FU - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 26 I/O, 100...240 V AC - Schneider Electric - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 26 I/O, 100...240 V AC - Schneider Electric - 1
SR3PACK2FU - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 26 I/O, 100...240 V AC - Schneider Electric - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 26 I/O, 100...240 V AC - Schneider Electric - 2
SR3PACK2FU - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 26 I/O, 100...240 V AC - Schneider Electric - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 26 I/O, 100...240 V AC - Schneider Electric - 3
SR3PACK2FU - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 26 I/O, 100...240 V AC - Schneider Electric - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 26 I/O, 100...240 V AC - Schneider Electric - 4
SR3PACK2FU - Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 26 I/O, 100...240 V AC - Schneider Electric
378,89 € excl. VAT
462,25 € incl. VAT
Text About:
Modular discovery packs, Zelio Logic, smart relay discoveryќ pack, 26 I/O, 100...240 V AC - Schneider Electric
462,25 €
SPECIFICATIONS
Main
Discrete input current 0.6 mA
maximum supply current 100 mA at 100 V (without extension)
50 mA at 240 V (without extension)
60 mA at 240 V (with extensions)
80 mA at 100 V (with extensions)
Complementary
Kit composition Cable PC SR2USB01 for connection to PC
SR3B261FU
local display With
Product certifications GL
UL
C-Tick
CSA
GOST
response time 50 ms with ladder programming (from state 0 to state 1) for discrete input
50 ms with ladder programming (from state 1 to state 0) for discrete input
50...255 ms with FBD programming (from state 0 to state 1) for discrete input
50...255 ms with FBD programming (from state 1 to state 0) for discrete input
10 ms (from state 0 to state 1) for relay output
5 ms (from state 1 to state 0) for relay output
Product or component type Modular discovery packs
tightening torque 0.5 N.m
[uimp] rated impulse withstand voltage 4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1
[us] rated supply voltage 100...240 V
Discrete input frequency 47...53 Hz
57...63 Hz
Connections - terminals Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid
Screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid
Screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end
current state 0 guaranteed <= 0.5 mA (discrete input)
output thermal current 5 A for 2 outputs for relay output
8 A for 8 outputs for relay output
current state 1 guaranteed >= 0.17 mA (discrete input)
Contacts type and composition NO for relay output
Clock With
clock drift 12 min/year at 0…55 °C
6 s/month at 25 °C
number of outputs 10 relay
supply voltage limits 85…264 V
Discrete input voltage 100...240 V AC
Discrete input number 16
Disturbance radiated/conducted Class B conforming to EN 55022-11 group 1
Net weight 0.85 kg
voltage state 1 guaranteed >= 79 V for discrete input
Immunity to microbreaks 10 ms
input impedance 350 kOhm for discrete input
switching capacity in ma >= 10 mA at 12 V (relay output)
mechanical durability 10000000 cycles for relay output
backup time 10 years at 25 °C
electrical durability AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1
DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1
DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1
output voltage limits 5...30 V DC (relay output)
24...250 V AC
voltage state 0 guaranteed <= 40 V for discrete input
Pollution degree 2 conforming to EN/IEC 61131-2
Power consumption in va 12 VA without extension
17 VA with extensions
Maximum altitude transport 3048 m
Isolation voltage 1780 V
Input/output number 26
cycle time 6…90 ms
Supply frequency 50/60 Hz
Number or control scheme lines 120 with ladder programming
0…200 with FBD programming
Operating rate in hz 0.1 Hz (at Ie) for relay output
10 Hz (no load) for relay output
Protection type Against inversion of terminals (control instructions not executed)
checks Program memory on each power up
Environment
Ambient air temp for storage/transportation -40…70 °C
ip degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (front panel) conforming to IEC 60529
operating altitude 2000 m
Range of product Zelio Logic
ambient air temperature for operation -20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2
-20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
Environmental characteristics EMC directive conforming to EN/IEC 61000-6-2
EMC directive conforming to EN/IEC 61000-6-3
EMC directive conforming to EN/IEC 61000-6-4
EMC directive conforming to EN/IEC 61131-2 zone B
Low voltage directive conforming to EN/IEC 61131-2
overvoltage category III conforming to EN/IEC 60664-1
standards EN/IEC 61000-4-5
EN/IEC 61000-4-2 level 3
EN/IEC 60068-2-27 Ea
EN/IEC 61000-4-3
EN/IEC 60068-2-6 Fc
EN/IEC 61000-4-6 level 3
EN/IEC 61000-4-11
EN/IEC 61000-4-4 level 3
EN/IEC 61000-4-12
relative humidity 95 % without condensation or dripping water
Recently viewed
378,89 € excl. VAT
462,25 € incl. VAT
Expected in 2-4 weeks