All categories
Compare Cart

RMCL55BD - Harmony Analog, Voltage/current converter, Isolated 0...20 mA - Schneider Electric

Expected in 2-4 weeks
RMCL55BD - Harmony Analog, Voltage/current converter, Isolated 0...20 mA - Schneider Electric - Harmony Analog, Voltage/current converter, Isolated 0...20 mA - Schneider Electric - 0
RMCL55BD - Harmony Analog, Voltage/current converter, Isolated 0...20 mA - Schneider Electric
123,29 € excl. VAT
150,42 € incl. VAT
Text About:
Harmony Analog, Voltage/current converter, Isolated 0...20 mA - Schneider Electric
150,42 €
SPECIFICATIONS
Main
[ui] rated insulation voltage 2 kV
Complementary
Product certifications UL
GL
CSA
Product or component type Voltage/current converter
tightening torque 0.6…1.1 N.m
[us] rated supply voltage 24 V DC +/- 20 %, isolated
Current consumption <= 70 mA for voltage output
<= 90 mA for current output
abnormal analog output current 22…30 mA, output selected 0...20 mA no input or input wire broken voltage
22…30 mA, output selected 4...20 mA no input or input wire broken voltage
-30…0 mA, output selected 0...20 mA no input or input wire broken current
4…30 mA, output selected 4...20 mA no input or input wire broken current
marking CE
temperature coefficient 200 ppm/°C
Analogue input type Current 0...20 mA
Current 4...20 mA
Voltage +/- 10 V DC
Voltage 0...10 V DC
Clamping connection capacity 2 x 1.5 mm²
1 x 2.5 mm²
Fixing mode By screws (mounting plate)
Clip-on (35 mm symmetrical DIN rail)
safety reliability data B10d = 20000
MTTFd = 21.6 years
Analogue output type Current 0...20 mA <= 500 Ohm switchable
Current 4...20 mA <= 500 Ohm switchable
Voltage +/- 10 V >= 100 kOhm switchable
Voltage 0...10 V >= 100 kOhm switchable
Local signalling LED (green) for power ON
Disturbance radiated/conducted CISPR 22 group 1 - class B
CISPR 11
Net weight 0.12 kg
measurement error +/- 10 % of full scale at 20 °C (electromagnetic interference of 10 V/m)
+/- 1 % of full scale at 20 °C
abnormal analog output voltage 11...15 V, output selected - 10...10 V no input or input wire broken voltage
11...15 V, output selected 0...10 V no input or input wire broken voltage
-15...0 V, output selected 0...20 mA no input or input wire broken current
-15...0 V, output selected 4...20 mA no input or input wire broken current
repeat accuracy +/- 0.2 % full scale at 20 °C
+/- 0.6 % full scale at 60 °C
Pollution degree 2 conforming to IEC 60664-1
Resistance to electrostatic discharge 6 kV (in contact) conforming to IEC 61000-4-2 level 3
8 kV (in air) conforming to IEC 61000-4-2 level 3
Shock resistance 50 gn for 11 ms conforming to IEC 60068-2-27
Surge withstand 0.5 kV during 1.2/50 µs conforming to IEC 61000-4-5
Protection type Reverse polarity protection on output
Short-circuit protection on output
Overvoltage protection on output (+/- 30 V)
Environment
Ambient air temp for storage/transportation -40…85 °C
ip degree of protection IP20 (terminal block)
IP50 (housing)
Range of product Harmony Analog
ambient air temperature for operation 0…50 °C mounting side by side
0…60 °C 2 cm spacing
standards IEC 60947-1
IEC 60584-1
fire resistance 850 °C conforming to IEC 60695-2-1
850 °C conforming to UL
vibration resistance 5 gn (f= 10…100 Hz) conforming to IEC 60068-2-6
resistance to fast transients 1 kV (on input-output) conforming to IEC 61000-4-4
2 kV (on power supply) conforming to IEC 61000-4-4
Recently viewed
123,29 € excl. VAT
150,42 € incl. VAT