Complementary
maximum power consumption in va
5 VA AC
Product certifications
C-Tick
GOST
UL
GL
CSA
response time
15 ms max (on crossing the threshold)
output contacts
1 C/O
Product or component type
Speed control relay
tightening torque
0.6…1 N.m conforming to IEC 60947-1
[us] rated supply voltage
24...240 V AC/DC
Impulse duration
>= 5 ms high state
>= 5 ms low state
Connections - terminals
Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
minimum switching current
10 mA at 5 V DC
marking
CE : EMC 89/336/EEC
CE : 73/23/EEC
Contacts material
Cadmium free
Delay at power up
0.05 s
hysteresis
5 % of threshold
width (w)
35 mm
supply voltage limits
20.4…264 V AC/DC
measurement error
+/- 0.1 %/°C with temperature variation
< +/- 1 % over the whole range with voltage variation
Input frequency
0.0017…20 Hz
measurement accuracy
+/- 10 % of the full scale value
Operating position
Any position without derating
Immunity to microbreaks
50 ms
Mounting support
35 mm symmetrical DIN rail conforming to EN/IEC 60715
Maximum supply current for sensors
40 mA for < 24 V AC at 25 °C
40 mA for < 24 V DC at 25 °C
50 mA for 24...240 V AC
50 mA for 24...240 V DC
mechanical durability
30000000 cycles
electrical durability
100000 cycles
repeat accuracy
+/- 0.5 % for input and measurement circuit
+/- 0.5 % for time delay
Housing material
Self-extinguishing plastic
Pollution degree
3 conforming to IEC 60664-1
Time delay range
0.6...60 s adjustable on energisation delay (tolerance: 0...10 % of the full scale value)
maximum power consumption in w
3 W DC
polarity
Reversible polarity on DC supply
Maximum switching voltage
250 V AC/DC
Operating rate
<= 360 operations/hour full load
Input compatibility
3-wire sensor (E1) PNP or NPN, 12 V, 50 mA
NAMUR sensor (E2), 12 V, 1.5 kOhm
Voltage input (E1), 0...30 V, 9.5 kOhm, high state >= 4.5 V low state <= 1 V
Volt-free contact input (E1), 12 V, 9.5 kOhm
Shock resistance
15 gn for 11 ms conforming to IEC 60255-21-1
operating voltage tolerance
- 15 % + 10 % Un
Status led
1 LED green for power ON
1 LED yellow for inhibit
1 LED yellow for relay (R)
Supply frequency
50/60 Hz +/- 10 %
Rest time in memory mode
50 ms contact S2 in memory mode on time delay
1 s supply Un in memory mode on time delay
Utilisation category
AC-12 conforming to IEC 60947-5-1
AC-13 conforming to IEC 60947-5-1
AC-14 conforming to IEC 60947-5-1
AC-15 conforming to IEC 60947-5-1
DC-12 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
DC-14 conforming to IEC 60947-5-1
Nominal output current
5 A
Supply voltage for sensor
11.5...12.5 V
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP20 (terminals) conforming to IEC 60529
IP30 (casing) conforming to IEC 60529
Range of product
Harmony Control Relays
ambient air temperature for operation
-20…50 °C
electromagnetic compatibility
Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
Non-dissipating shock wave
4 kV
overvoltage category
III conforming to IEC 60664-1
standards
NF EN 60255-6
IEC 60255-6
relative humidity
95 % at 55 °C conforming to IEC 60068-2-30
vibration resistance
0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
1 gn (f= 57.6…150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
dielectric test voltage
2 kV AC 50 Hz
insulation resistance
> 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5
> 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1
> 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5
> 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1
> 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5
> 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1