All categories
Compare Cart

RM35JA32MT - Harmony, Modular 1phase current control relay, 8 A, 2 CO, 150 mA?¦15 A, 380?¦415 V AC - Schneider Electric

Expected in 2-4 weeks
RM35JA32MT - Harmony, Modular 1phase current control relay, 8 A, 2 CO, 150 mA?¦15 A, 380?¦415 V AC - Schneider Electric - Harmony, Modular 1phase current control relay, 8 A, 2 CO, 150 mA?¦15 A, 380?¦415 V AC - Schneider Electric - 0
RM35JA32MT - Harmony, Modular 1phase current control relay, 8 A, 2 CO, 150 mA?¦15 A, 380?¦415 V AC - Schneider Electric - Harmony, Modular 1phase current control relay, 8 A, 2 CO, 150 mA?¦15 A, 380?¦415 V AC - Schneider Electric - 1
RM35JA32MT - Harmony, Modular 1phase current control relay, 8 A, 2 CO, 150 mA?¦15 A, 380?¦415 V AC - Schneider Electric - Harmony, Modular 1phase current control relay, 8 A, 2 CO, 150 mA?¦15 A, 380?¦415 V AC - Schneider Electric - 2
RM35JA32MT - Harmony, Modular 1phase current control relay, 8 A, 2 CO, 150 mA?¦15 A, 380?¦415 V AC - Schneider Electric - Harmony, Modular 1phase current control relay, 8 A, 2 CO, 150 mA?¦15 A, 380?¦415 V AC - Schneider Electric - 3
RM35JA32MT - Harmony, Modular 1phase current control relay, 8 A, 2 CO, 150 mA?¦15 A, 380?¦415 V AC - Schneider Electric
122,22 € excl. VAT
149,11 € incl. VAT
Text About:
Harmony, Modular 1phase current control relay, 8 A, 2 CO, 150 mA?¦15 A, 380?¦415 V AC - Schneider Electric
149,11 €
SPECIFICATIONS
Main
Measurement range 0.15...1.5 A E1-M terminals
0.5...5 A E2-M terminals
1.5...15 A E3-M terminals
150 mA...15 A current AC/DC 50/60 Hz
Relay monitored parameters Overcurrent or undercurrent detection
Overcurrent or undercurrent in window mode
switching capacity in va 2000 VA
Relay type Current control relay
relay name RM35JA
threshold setting 10...100 %
Complementary
maximum power consumption in va 8 VA
maximum switching current 8 A AC
Product certifications CCC
EAC
CSA
RCM
UL
GL
CE
response time <= 500 ms (on crossing the threshold)
output contacts 2 C/O
Product or component type Current control relay
tightening torque 0.6…1 N.m conforming to IEC 60947-1
[us] rated supply voltage 380...415 V AC 50/60 Hz +/- 10 %
Connections - terminals Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
minimum switching current 10 mA at 5 V DC
reset time 1500 ms at maximum voltage
Contacts material Cadmium free
Delay at power up 0.3 s
hysteresis 5…50 % adjustable of threshold setting
3 % fixed of full scale for window mode
Contacts type and composition 2 C/O
safety reliability data MTTFd = 296.8 years
B10d = 270000
maximum measuring cycle 100 ms measurement cycle as true rms value
width (w) 35 mm
supply voltage limits 323…456.5 V AC
Local signalling LED (yellow) for relay ON
LED (green) for power ON
switching threshold drift <= 0.05 % per degree centigrade depending permissible ambient air temperature
<= 1 % within the supply voltage range
Net weight 0.12 kg
measurement error < 1 % over the whole range with voltage variation
0.05 %/°C with temperature variation
Internal input resistance 0.005 Ohm
0.015 Ohm
0.05 Ohm
Immunity to microbreaks 50 ms
Mounting support 35 mm DIN rail conforming to EN/IEC 60715
mechanical durability 10000000 cycles
electrical durability 100000 cycles
repeat accuracy +/- 0.5 % for input and measurement circuit
+/- 2 % for time delay
Housing material Self-extinguishing plastic
Pollution degree 3 conforming to IEC 60664-1
3 conforming to UL 508
Maximum switching voltage 250 V AC
Insulation Between supply and measurement
Shock resistance 15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27
5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27
operating voltage tolerance - 15 % + 10 % Un
Resistance across terminals 0.005 Ohm at E3-M terminals
0.015 Ohm at E2-M terminals
0.05 Ohm at E1-M terminals
Setting accuracy of the switching threshold +/- 10 % of the full scale
+/- 20 % of the full scale
Utilisation category AC-15 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
AC-1 conforming to IEC 60947-4-1
DC-1 conforming to IEC 60947-4-1
Nominal output current 8 A
Time delay Adjustable 0.1...30 s, +/- 10 % of the full scale value on crossing the threshold Tt
Setting accuracy of time delay 10 P
Time delay drift <= 0.05 % per degree centigrade depending permissible ambient air temperature
<= 1 % within the supply voltage range
Environment
Ambient air temp for storage/transportation -40…70 °C
ip degree of protection IP20 (terminals) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
IP30 (housing) conforming to IEC 60529
Range of product Harmony Control Relays
ambient air temperature for operation -20…50 °C at 60 Hz
-20…60 °C at 50 Hz
electromagnetic compatibility Immunity for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-1
Immunity for industrial environments conforming to EN/IEC 61000-6-2
Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test - test level: 4 kV level 4 (direct) conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV level 4 (capacitive coupling) conforming to IEC 61000-4-4
Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5
Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5
Conducted and radiated emissions class B group 1 conforming to CISPR 11
Conducted and radiated emissions class B conforming to CISPR 22
Emission standard for residential, commercial and light-industrial environments (except radiated emission) conforming to EN/IEC 61000-6-3
Environmental characteristics 3K3 C
overvoltage category III conforming to IEC 60664-1
III conforming to UL 508
standards EN/IEC 60255-1
relative humidity 93…97 % at 25…55 °C conforming to IEC 60068-2-30
vibration resistance 0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
1 gn (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6
0.035 mm (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6
dielectric test voltage 2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27
insulation resistance > 100 MOhm at 500 V DC conforming to IEC 60255-27