Main
Measurement range
40...70 Hz frequency
Relay monitored parameters
Overfrequency and underfrequency 50 or 60 Hz
switching capacity in va
1250 VA
Relay type
Frequency control relays
relay name
RM35HZ21FM
[ui] rated insulation voltage
400 V conforming to IEC 60664-1
threshold setting
-2...10 Hz
-10...2 Hz
Complementary
maximum power consumption in va
6 VA AC
Product certifications
GL
UL
CSA
C-Tick
GOST
output contacts
1 C/O + 1 C/O
Product or component type
Frequency control relay
tightening torque
0.6…1 N.m conforming to IEC 60947-1
[us] rated supply voltage
120...277 V AC
Connections - terminals
Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
minimum switching current
10 mA at 5 V DC
marking
CE : 73/23/EEC
CE : EMC 89/336/EEC
reset time
2000 ms time delay
Contacts material
Cadmium free
Delay at power up
0.5 s
hysteresis
0.3 % fixed
maximum measuring cycle
200 ms measurement cycle as true rms value
width (w)
35 mm
control circuit frequency
40...70 Hz
supply voltage limits
102…308 V AC
Local signalling
1 LED green for power ON
1 LED yellow for correct frequency (high R1)
1 LED yellow for correct frequency (low R2)
measurement error
+/- 0.05 %/°C with temperature variation
< +/- 1 % over the whole range with voltage variation
measurement accuracy
+/- 10 % of the full scale value in input
+/- 10 % of the full scale value in time delay
Operating position
Any position without derating
Immunity to microbreaks
10 ms
Mounting support
35 mm symmetrical DIN rail conforming to EN/IEC 60715
mechanical durability
30000000 cycles
electrical durability
100000 cycles
repeat accuracy
+/- 0.5 % for input and measurement circuit
+/- 0.5 % for time delay
Maximum input frequency
70 Hz
Housing material
Self-extinguishing plastic
Pollution degree
3 conforming to IEC 60664-1
Maximum switching voltage
250 V AC/DC
Insulation
No galvanic insulation between supply and measurement
Operating rate
<= 360 operations/hour full load
Shock resistance
15 gn for 11 ms conforming to IEC 60255-21-1
operating voltage tolerance
- 15 % + 10 % Un
Supply frequency
50/60 Hz +/- 10 %
Utilisation category
AC-12 conforming to IEC 60947-5-1
AC-13 conforming to IEC 60947-5-1
AC-14 conforming to IEC 60947-5-1
AC-15 conforming to IEC 60947-5-1
DC-12 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
DC-14 conforming to IEC 60947-5-1
Nominal output current
5 A
Time delay type
Adjustable 0.1...10 s, +/- 10 % on crossing the threshold
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP20 (terminals) conforming to IEC 60529
IP30 (casing) conforming to IEC 60529
Range of product
Harmony Control Relays
ambient air temperature for operation
-20…50 °C
electromagnetic compatibility
Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
Non-dissipating shock wave
4 kV
overvoltage category
III conforming to IEC 60664-1
standards
IEC 60255-6
NF EN 60255-6
relative humidity
95 % at 55 °C conforming to IEC 60068-2-30
vibration resistance
0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
1 gn (f= 57.6…150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
dielectric test voltage
2 kV AC 50 Hz
insulation resistance
> 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60255-5
> 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60664-1
> 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60255-5
> 500 MOhm at 500 V DC between supply and relay output conforming to IEC 60664-1
> 500 MOhm at 500 V DC between measurement and relay output conforming to IEC 60255-5
> 1 MOhm at 500 V DC between supply and measurement conforming to IEC 60664-1