Complementary
[un] rated nominal voltage
208...480 V AC 3 phases
230 V AC 1 phase
maximum power consumption in va
5 VA AC
maximum switching current
5 A AC/DC
Product certifications
C-Tick
CSA
GOST
UL
GL
response time
< 300 ms (in the event of a fault)
output contacts
1 C/O
Product or component type
Pump control relay
tightening torque
0.6…1 N.m conforming to IEC 60947-1
Connections - terminals
Screw terminals, 1 x 0.5...1 x 4 mm² (AWG 20...AWG 11) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 12) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
minimum switching current
10 mA at 5 V DC
marking
CE : EMC 89/336/EEC
CE : 73/23/EEC
reset time
2000 ms
Delay at power up
0.5 s
hysteresis
5 % of threshold
maximum measuring cycle
140 ms as true rms value
width (w)
35 mm
supply voltage limits
183…528 V AC
measurement error
1 % by volt over the whole range
+/- 0.05 %/°C
measurement accuracy
+/- 10 % of the full scale value
Operating position
Any position
Immunity to microbreaks
500 ms
Mounting support
35 mm symmetrical DIN rail conforming to EN/IEC 60715
mechanical durability
30000000 cycles
electrical durability
100000 cycles
repeat accuracy
+/- 1 % for input and measurement circuit
+/- 1 % for time delay
Housing material
Self-extinguishing plastic
Pollution degree
3 conforming to IEC 60664-1
Maximum switching voltage
250 V AC/DC
dielectric strength
2 kV AC 50 Hz (shock wave 4 kV)
Operating rate
<= 360 operations/hour full load
Overload input current
11 A permanent at 25 °C E1-L2 terminals
50 A non repetitive < 1 s at 25 °C E1-L2 terminals
Shock resistance
15 gn for 11 ms conforming to IEC 60255-21-1
operating voltage tolerance
- 15 % + 10 % Un
Resistance across terminals
0.01 Ohm at E1-L2 terminals
Status led
1 LED green for power ON
1 LED yellow for fault
1 LED yellow for relay ON
Supply frequency
50/60 Hz +/- 10 %
Utilisation category
AC-12 conforming to IEC 60947-5-1
AC-13 conforming to IEC 60947-5-1
AC-14 conforming to IEC 60947-5-1
AC-15 conforming to IEC 60947-5-1
DC-12 conforming to IEC 60947-5-1
DC-13 conforming to IEC 60947-5-1
Nominal output current
5 A
Time delay type
Adjustable 1...60 s, +/- 10 % Ti on energisation
Fixed 0.3 s reset on terminal Y2
Adjustable 0.1...10 s, +/- 10 % Tt on crossing the threshold
Environment
Ambient air temp for storage/transportation
-40…70 °C
ip degree of protection
IP20 (terminals) conforming to IEC 60529
IP30 (casing) conforming to IEC 60529
Range of product
Harmony Control Relays
ambient air temperature for operation
-20…50 °C
electromagnetic compatibility
Emission standard for industrial environments conforming to EN/IEC 61000-6-4
Emission standard for residential, commercial and light-industrial environments conforming to EN/IEC 61000-6-3
Immunity for industrial environments conforming to NF EN/IEC 61000-6-2
overvoltage category
III conforming to IEC 60664-1
standards
EN/IEC 60255-6
relative humidity
95 % at 55 °C conforming to IEC 60068-2-30
vibration resistance
0.35 mm (f= 5…57.6 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
1 gn (f= 57.6…150 Hz) conforming to IEC 60068-2-6/IEC 60255-21-1
insulation resistance
> 500 MOhm at 500 V DC between supply and relay output conforming to 60255-5
> 500 MOhm at 500 V DC between measurement and relay output conforming to 60664-1
> 1 MOhm at 500 V DC between supply and measurement conforming to 60255-5
> 500 MOhm at 500 V DC between supply and relay output conforming to 60664-1
> 500 MOhm at 500 V DC between measurement and relay output conforming to 60255-5
> 1 MOhm at 500 V DC between supply and measurement conforming to 60664-1