All categories
Compare Cart

RE22R2QEMT - Harmony, Modular timing relay, 8 A, 2 CO, 0.3 s?¦30 s, star delta, 380?¦415 V AC/DC - Schneider Electric

Expected in 2-4 weeks
RE22R2QEMT - Harmony, Modular timing relay, 8 A, 2 CO, 0.3 s?¦30 s, star delta, 380?¦415 V AC/DC - Schneider Electric - Harmony, Modular timing relay, 8 A, 2 CO, 0.3 s?¦30 s, star delta, 380?¦415 V AC/DC - Schneider Electric - 0
RE22R2QEMT - Harmony, Modular timing relay, 8 A, 2 CO, 0.3 s?¦30 s, star delta, 380?¦415 V AC/DC - Schneider Electric
84,99 € excl. VAT
103,68 € incl. VAT
Text About:
Harmony, Modular timing relay, 8 A, 2 CO, 0.3 s?¦30 s, star delta, 380?¦415 V AC/DC - Schneider Electric
103,68 €
SPECIFICATIONS
Main
Device short name RE22
switching capacity in va 2000 VA
Complementary
Control type Rotary knob
Diagnostic button
maximum switching current 8 A
Product certifications EAC
GL
CSA
UL
CCC
RCM
CE
Product or component type Single function relay
tightening torque 0.6…1 N.m conforming to IEC 60947-1
[us] rated supply voltage 380...415 V AC 50/60 Hz
Connections - terminals Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
minimum switching current 10 mA at 5 V DC
Contacts type and composition 2 C/O timed contact, cadmium free
safety reliability data B10d = 250000
MTTFd = 273.9 years
width (w) 22.5 mm
Creepage distance 4 kV/3 conforming to IEC 60664-1
temperature drift +/- 0.05 %/°C
Net weight 0.09 kg
voltage drift +/- 0.2 %/V
Discrete output type Relay
Immunity to microbreaks 10 ms
Mounting support 35 mm DIN rail conforming to EN/IEC 60715
mechanical durability 10000000 cycles
electrical durability 100000 cycles, 8 A at 250 V, AC-1
100000 cycles, 2 A at 24 V, DC-1
repeat accuracy +/- 0.5 % conforming to IEC 61812-1
Housing material Self-extinguishing
Pollution degree 3 conforming to IEC 60664-1
Power consumption in va 15 VA at 380 V AC
Time delay range 0.3...30 s
mounting position Any position
Maximum switching voltage 250 V AC
dielectric strength 2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1
recovery time 120 ms on de-energisation
rated impulse withstand voltage 5 kV for 1.2…50 µs conforming to IEC 60664-1
Shock resistance 15 gn not operating for 11 ms conforming to IEC 60068-2-27
5 gn in operation for 11 ms conforming to IEC 60068-2-27
Release input voltage <= 38 V
Status led LED backlight green (steady) for dial pointer indication
LED yellow (steady) for output relay energised
LED yellow (fast flashing) for timing in progress and output relay de-energised
LED yellow (slow flashing) for timing in progress and output relay energised
Supply frequency 50...60 Hz +/- 5 %
Power on delay 100 ms
Nominal output current 8 A
Setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Time delay type Star-delta
Voltage range 0.85...1.16 Us
Environment
Ambient air temp for storage/transportation -40…70 °C
Directives 2006/95/EC - low voltage directive
2004/108/EC - electromagnetic compatibility
ip degree of protection IP40 housing: conforming to IEC 60529
IP20 terminals: conforming to IEC 60529
IP50 front panel: conforming to IEC 60529
Range of product Harmony Timer Relays
ambient air temperature for operation -20…60 °C
electromagnetic compatibility Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4
Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2
Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3
Conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6
Fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4
Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
Surge immunity test - test level: 2 kV level 3 (differential mode) conforming to IEC 61000-4-5
Surge immunity test - test level: 4 kV level 3 (common mode) conforming to IEC 61000-4-5
overvoltage category III conforming to IEC 60664-1
standards IEC 61812-1
UL 508
relative humidity 95 % at 25…55 °C
vibration resistance 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1
Recently viewed
84,99 € excl. VAT
103,68 € incl. VAT
Expected in 2-4 weeks