Complementary
[ics] rated service breaking capacity
2000 VA
Control type
Rotary knob front panel
maximum switching current
8 mA
Product certifications
cULus
CSA
CE
CCC
RCM
GL
EAC
Product or component type
Multifunction relay
tightening torque
0.6…1 N.m conforming to IEC 60947-1
[us] rated supply voltage
24...240 V AC
24 V DC
Connections - terminals
Screw terminals, 2 x 1.5 mm² with cable end
Screw terminals, 2 x 2.5 mm² without cable end
minimum switching current
10 mA at 5 V
Contacts type and composition
1 C/O timed contact
1 C/O timed or instantaneous contact
safety reliability data
MTTFd = 182.6 years
B10d = 170000
width (w)
22.5 mm
temperature drift
+/- 0.05 %/°C
Net weight
0.09 kg
voltage drift
+/- 0.2 %/V
Discrete output type
Relay
Immunity to microbreaks
10 ms
Mounting support
35 mm DIN rail conforming to EN/IEC 60715
mechanical durability
10000000 cycles
electrical durability
100000 cycles for resistive load, 8 A at 250 V, AC
repeat accuracy
+/- 0.5 % conforming to IEC 61812-1
control signal pulse width
30 ms
100 ms under load
Housing material
Self-extinguishing
Power consumption in va
50 VA at 240 V AC
Power consumption in w
0.7 W at 24 V DC
Time delay range
10...100 h
6...60 s
0.1...1 s
1...10 h
1...10 s
1...10 min
6...60 min
mounting position
Any position in relation to normal vertical mounting plane
Maximum switching voltage
250 V
dielectric strength
2.5 kV for 1 mA/1 minute at 50 Hz conforming to IEC 61812-1
recovery time
120 ms on de-energisation
rated impulse withstand voltage
5 kV for 1.2…50 µs conforming to IEC 60664-1
5 kV conforming to IEC 61812-1
Shock resistance
15 gn for 11 ms conforming to IEC 60068-2-27
Status led
LED green (flashing) for timing in progress
LED green (steady) for power ON
LED yellow for relay energised
Supply frequency
50...60 Hz +/- 5 %
Power on delay
100 ms
Nominal output current
8 A
Setting accuracy of time delay
+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Time delay type
Power on-delay
On-delay and off-delay
Interval
Off-delay
Symmetrical flashing
Voltage range
0.85...1.1 Us
Environment
Ambient air temp for storage/transportation
-30…60 °C
Directives
2004/108/EC - electromagnetic compatibility
2006/95/EC - low voltage directive
ip degree of protection
IP40 housing: conforming to IEC 60529
IP20 terminal block: conforming to IEC 60529
IP40 front face: conforming to IEC 60529
Range of product
Harmony Timer Relays
ambient air temperature for operation
-20…60 °C
electromagnetic compatibility
Electrostatic discharge immunity test - test level: 6 kV level 3 (contact discharge) conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test - test level: 8 kV level 3 (air discharge) conforming to EN/IEC 61000-4-2
Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4
Fast transients immunity test - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4
Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5
Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5
Radiated radio-frequency electromagnetic field immunity test - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6
Electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3
Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11
Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
Conducted and radiated emissions class B conforming to EN 55022
standards
IEC 61812-1
EN 61000-6-1
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
relative humidity
93 %, without condensation conforming to IEC 60068-2-30
vibration resistance
20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
insulation resistance
100 MOhm at 500 V DC conforming to IEC 60664-1