All categories
Compare Cart

RE22R1AMR - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric

Expected in 2-4 weeks EAN: 3606480792366
RE22R1AMR - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric - 0
RE22R1AMR - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric - 1
RE22R1AMR - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric - 2
RE22R1AMR - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric - 3
RE22R1AMR - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric - 4
RE22R1AMR - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric - 5
RE22R1AMR - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric - 6
EAN: 3606480792366
RE22R1AMR - Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric
43,00 € excl. VAT
52,46 € incl. VAT
Text About:
Modular timing relay, Harmony, 8A, 1 CO, 0.05s…300h, power on delay, 24...240V AC DC - Schneider Electric
52,46 €
SPECIFICATIONS
Main
product range Relais de temporisation Harmony
switching capacity in va 2000 VA
name of the device RE22
type of product or equipment Relais double fonction
rated output current 8 A
timer type Puissance d'enclenchement
Complementary
[un] rated nominal voltage 24…240 V CA/CC 50/60 Hz
maximum switching current 8 A
tightening torque 0,6…1 N.m se conformer à CEI 60947-1
case material Auto-extinguible
minimum switching current 10 mA à 5 V CC
product weight 0,1 kg
power consumed in va 3 VA à 240 V CA
electrical life 100000 cycle, 8 A à 250 V, AC-1
100000 cycle, 2 A à 24 V, DC-1
escape distance 4 kV/3 se conformer à CEI 60664-1
led status Vert rétro-éclairage à DEL (fixe) pour indication de l’aiguille du cadran
Jaune LED (fixe) pour relais de sortie sous tension
Jaune LED (clignotement rapide) pour temporisation en cours et relais de sortie hors tension
Jaune LED (clignotement lent) pour temporisation en cours et relais de sortie sous tension
connection mode Bornes à vis, 1 x 0,5 à 1 x 3,3 mm² (AWG 20 à AWG 12) rigide sans embout
Bornes à vis, 2 x 0,5 à 2 x 2,5 mm² (AWG 20 à AWG 14) rigide sans embout
Bornes à vis, 1 x 0,2 à 1 x 2,5 mm² (AWG 24…AWG 14) souple avec embout
Bornes à vis, 2 x 0,2 à 2 x 1,5 mm² (AWG 24 à AWG 16) souple avec embout
safety reliability data MTTFd = 308,2 années
B10d = 280000
mechanical endurance 10000000 cycle
width (w) 22,5 mm
power frequency 50...60 Hz +/- 5 %
power-on delay 100 ms
temperature drift +/- 0,05 %/°C
voltage drift +/- 0,2 %/V
timing range 3...30 s
30...300 s
10...100 s
0,05...1 s
1…10 s
30...300 H
30...300 min
0,3…3 s
3...30 H
3...30 min
power consumed in w 1,5 W à 240 V CC
mounting bracket Rail DIN 35 mm se conformer à EN/CEI 60715
repeat accuracy +/- 0,5% se conformer à CEI 61812-1
control signal pulse width 100 ms avec charge en parallèle
30 ms
input voltage release <= 2,4 V
mounting position Toutes positions
order type Bouton rotatif
Bouton de diagnostic
type and composition of contacts 1 F/O contact temporisé, sans cadmium
voltage range of use 0,85 à 1,1 Us
dielectric strength 2,5 kV pour 1 mA/1 minute à 50 Hz entre sortie de relais et alimentation avec isolement de base se conformer à CEI 61812-1
recovery time 120 ms sur désexcitation
rated impulse withstand voltage 5 kV pour 1,2…50 µs se conformer à CEI 60664-1
exact adjustment of the delay time +/- 10 % pleine échelle à 25 °C se conformer à CEI 61812-1
maximum cut-off voltage 250 V CA
logic output type Relais
Environment
degree of pollution 3 se conformer à CEI 60664-1
ip degree of protection IP40 enveloppe: se conformer à CEI 60529
IP50 face avant: se conformer à CEI 60529
IP20 bornes: se conformer à CEI 60529
product certificates CE
UL
GL
CCC
EAC
RCM
CSA
electromagnetic compatibility Test d'immunité des transitoires rapides - niveau de test : 1 kV (clip de connexion capacitive)niveau 3 se conformer à CEI 61000-4-4
Test d’immunité aux surtensions - niveau de test : 1 kV (mode différentiel)niveau 3 se conformer à CEI 61000-4-5
Test d’immunité aux surtensions - niveau de test : 2 kV (mode commun)niveau 3 se conformer à CEI 61000-4-5
Décharge électrostatique - niveau de test : 6 kV (décharge par contact)niveau 3 se conformer à CEI 6100-4-11
Décharge électrostatique - niveau de test : 8 kV (décharge dans l'air)niveau 3 se conformer à CEI 6100-4-11
Test d'immunité aux champs électromagnétiques radio-fréquences rayonnés - niveau de test : 10 V/m (80 MHz…1 GHz)niveau 3 se conformer à CEI 61000-4-3
Perturbations RF transmises par conduction - niveau de test : 10 V (0,15 à 80 MHz)niveau 3 se conformer à CEI 61000-4-6
Transitoire rapide en salves - niveau de test : 2 kV (contact direct)niveau 3 se conformer à CEI 61000-4-4
Immunité aux micro-coupures et baisses de tension - niveau de test : 30 % (500 ms) se conformer à CEI 61000-4-11
Immunité aux micro-coupures et baisses de tension - niveau de test : 100 % (20 ms) se conformer à CEI 61000-4-11
immunity to micro-breaks 10 ms
operating ambient temperature -20…60 °C
overvoltage category III se conformer à CEI 60664-1
standards UL 508
CEI 61812-1
relative humidity 95 % à 25…55 °C
storage room temperature -40…70 °C
mechanical shock resistance 15 gn non fonctionnant pour 11 ms se conformer à CEI 60068-2-27
5 gn en marche pour 11 ms se conformer à CEI 60068-2-27
European regulation 2006/95/CE - directive basse tension
2004/108/CE - compatibilité électromagnétique
vibration resistance 20 m/s² (f= 10…150 Hz) se conformer à CEI 60068-2-6
insulation resistance 100 MΩ à 500 V CC se conformer à CEI 60664-1
Recently viewed
43,00 € excl. VAT
52,46 € incl. VAT
Expected in 2-4 weeks