All categories
Compare Cart

RE17RMEMUS - Modular timing relay, Harmony, 8A, 1CO, 0.1s..10 h, multifunction, spring terminals, 24V DC 24...240V AC DC - Schneider Electric

Expected in 2-4 weeks
RE17RMEMUS - Modular timing relay, Harmony, 8A, 1CO, 0.1s..10 h, multifunction, spring terminals, 24V DC 24...240V AC DC - Schneider Electric - Modular timing relay, Harmony, 8A, 1CO, 0.1s..10 h, multifunction, spring terminals, 24V DC 24...240V AC DC - Schneider Electric - 0
RE17RMEMUS - Modular timing relay, Harmony, 8A, 1CO, 0.1s..10 h, multifunction, spring terminals, 24V DC 24...240V AC DC - Schneider Electric
69,59 € excl. VAT
84,90 € incl. VAT
Text About:
Modular timing relay, Harmony, 8A, 1CO, 0.1s..10 h, multifunction, spring terminals, 24V DC 24...240V AC DC - Schneider Electric
84,90 €
SPECIFICATIONS
Main
Device short name RE17R
Complementary
compatibility code RE17
[ics] rated service breaking capacity 2000 VA
Control type Selector switch front panel
maximum switching current 8 A AC/DC
Product certifications CSA
cULus
DNV-GL
EAC
CCC
Handle front plate colour 90 mm
Product or component type Multifunction relay
[uimp] rated impulse withstand voltage 5 kV during 1.2/50 µs
[us] rated supply voltage 24...240 V AC 50/60 Hz
24 V DC
Connections - terminals Spring terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid without cable end
Spring terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible without cable end
minimum switching current 10 mA at 5 V DC
marking CE
reset time 120 ms on de-energisation typical
Contacts material Cadmium free
Contacts type and composition 1 C/O
safety reliability data MTTFd = 296.8 years
B10d = 270000
width (w) 17.5 mm
On-load factor 100 %
Creepage distance 4 kV/3 conforming to IEC 60664-1
Local signalling LED indicator for on steady: relay energised, no timing in progress
LED indicator for flashing: timing in progress 80 % ON and 20 % OFF
LED indicator for pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) 5 % ON and 95 % OFF
temperature drift +/- 0.05 %/°C
Net weight 0.06 kg
voltage drift +/- 0.2 %/V
Discrete output type Relay
functionality Multifunction
Immunity to microbreaks 20 ms
Mounting support 35 mm DIN rail conforming to EN/IEC 60715
depth 72 mm
mechanical durability 10000000 cycles
electrical durability 100000 cycles (8 A at 250 V AC maximum) for resistive load
operating frequency 10 Hz
repeat accuracy +/- 0.5 % conforming to IEC 61812-1
control signal pulse width 100 ms with load in parallel typical
30 ms typical
Housing material Self-extinguishing
Power consumption in va 0…32 VA at 240 V AC
Time delay range 6...60 min
1...10 min
1...10 s
1...10 h
6...60 s
0.1...1 s
mounting position Any position in relation to normal vertical mounting plane
maximum power consumption in w 0.6 W at 24 V DC
Maximum switching voltage 250 V AC
dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Supply frequency 50...60 Hz +/- 5 %
Power on delay 100 ms
Release of input voltage 10 V
Nominal output current 8 A
Setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Time delay type A, At, B, C, D, Di, H, Ht
Voltage range 0.85...1.1 Us
Environment
Ambient air temp for storage/transportation -30…60 °C
ip degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
Range of product Harmony Timer Relays
ambient air temperature for operation -20…60 °C
electromagnetic compatibility Electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2
Electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5
Conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11
Voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11
Conducted and radiated emissions: , class B, conforming to EN 55022
standards 2004/108/EC
EN 61000-6-2
EN 61000-6-3
EN 61000-6-1
2006/95/EC
IEC 61812-1
EN 61000-6-4
relative humidity 93 % without condensation conforming to IEC 60068-2-30
vibration resistance 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1
Recently viewed
69,59 € excl. VAT
84,90 € incl. VAT
Expected in 2-4 weeks