Complementary
																					
												compatibility code
												RE17
											
                            
																					
												[ics] rated service breaking capacity
												2000 VA
											
                            
																					
												Control type
												Selector switch front panel
											
                            
																					
												maximum switching current
												8 A AC/DC
											
                            
																					
												Product certifications
												GL
cULus
CSA
											
                            
																					
												Handle front plate colour
												90 mm
											
                            
																					
												Product or component type
												Single function relay
											
                            
																					
												tightening torque
												0.6…1 N.m conforming to IEC 60947-1
											
                            
																					
												[uimp] rated impulse withstand voltage
												5 kV during 1.2/50 µs
											
                            
																					
												[us] rated supply voltage
												24...240 V AC 50/60 Hz
24 V DC
											
                            
																					
												Connections - terminals
												Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
											
                            
																					
												minimum switching current
												10 mA at 5 V DC
											
                            
																					
												marking
												CE
											
                            
																					
												reset time
												120 ms on de-energisation typical
											
                            
																					
												Contacts material
												Cadmium free
											
                            
																					
												Contacts type and composition
												1 C/O
											
                            
																					
												safety reliability data
												MTTFd = 296.8 years
B10d = 270000
											
                            
																					
												width (w)
												17.5 mm
											
                            
																					
												On-load factor
												100 %
											
                            
																					
												Creepage distance
												4 kV/3 conforming to IEC 60664-1
											
                            
																					
												Local signalling
												LED indicator for on steady: relay energised, no timing in progress
LED indicator for flashing: timing in progress 80 % ON and 20 % OFF
LED indicator for pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) 5 % ON and 95 % OFF
											
                            
																					
												temperature drift
												+/- 0.05 %/°C
											
                            
																					
												Net weight
												0.07 kg
											
                            
																					
												voltage drift
												+/- 0.2 %/V
											
                            
																					
												Discrete output type
												Relay
											
                            
																					
												functionality
												Pulse signal
											
                            
																					
												Immunity to microbreaks
												20 ms
											
                            
																					
												Mounting support
												35 mm DIN rail conforming to EN/IEC 60715
											
                            
																					
												depth
												72 mm
											
                            
																					
												mechanical durability
												10000000 cycles
											
                            
																					
												electrical durability
												100000 cycles (8 A at 250 V AC maximum) for resistive load
											
                            
																					
												operating frequency
												10 Hz
											
                            
																					
												repeat accuracy
												+/- 0.5 % conforming to IEC 61812-1
											
                            
																					
												control signal pulse width
												100 ms with load in parallel typical
30 ms typical
											
                            
																					
												Housing material
												Self-extinguishing
											
                            
																					
												Power consumption in va
												0…32 VA at 240 V AC
											
                            
																					
												Time delay range
												10...100 h
1...10 min
6...60 min
1...10 s
6...60 s
1...10 h
0.1...1 s
											
                            
																					
												mounting position
												Any position in relation to normal vertical mounting plane
											
                            
																					
												maximum power consumption in w
												0.6 W at 24 V DC
											
                            
																					
												Maximum switching voltage
												250 V AC
											
                            
																					
												dielectric strength
												2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
											
                            
																					
												Shock resistance
												15 gn for 11 ms conforming to IEC 60068-2-27
											
                            
																					
												Supply frequency
												50...60 Hz +/- 5 %
											
                            
																					
												Power on delay
												100 ms
											
                            
																					
												Release of input voltage
												10 V
											
                            
																					
												Nominal output current
												8 A
											
                            
																					
												Setting accuracy of time delay
												+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
											
                            
																					
												Time delay type
												B
											
                            
																					
												Voltage range
												0.85...1.1 Us
											
                            
																			 
																	
										Environment
																					
												Ambient air temp for storage/transportation
												-30…60 °C
											
                            
																					
												ip degree of protection
												IP20 (terminal block) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
											
                            
																					
												Range of product
												Harmony Timer Relays
											
                            
																					
												ambient air temperature for operation
												-20…60 °C
											
                            
																					
												electromagnetic compatibility
												Electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2
Electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5
Conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11
Voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11
Conducted and radiated emissions: , class B, conforming to EN 55022
											
                            
																					
												standards
												2006/95/EC
EN 61000-6-2
EN 61000-6-3
EN 61000-6-4
IEC 61812-1
EN 61000-6-1
2004/108/EC
											
                            
																					
												relative humidity
												93 % without condensation conforming to IEC 60068-2-30
											
                            
																					
												vibration resistance
												20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
											
                            
																					
												insulation resistance
												100 MOhm at 500 V DC conforming to IEC 60664-1