All categories
Compare Cart

RE17LMBM - Harmony, Modular timing relay, 0.7 A, 1 s..100 h, multifunction, solid state output, 24...240 V AC - Schneider Electric

Expected in 2-4 weeks
RE17LMBM - Harmony, Modular timing relay, 0.7 A, 1 s..100 h, multifunction, solid state output, 24...240 V AC - Schneider Electric - Harmony, Modular timing relay, 0.7 A, 1 s..100 h, multifunction, solid state output, 24...240 V AC - Schneider Electric - 0
RE17LMBM - Harmony, Modular timing relay, 0.7 A, 1 s..100 h, multifunction, solid state output, 24...240 V AC - Schneider Electric - Harmony, Modular timing relay, 0.7 A, 1 s..100 h, multifunction, solid state output, 24...240 V AC - Schneider Electric - 1
RE17LMBM - Harmony, Modular timing relay, 0.7 A, 1 s..100 h, multifunction, solid state output, 24...240 V AC - Schneider Electric - Harmony, Modular timing relay, 0.7 A, 1 s..100 h, multifunction, solid state output, 24...240 V AC - Schneider Electric - 2
RE17LMBM - Harmony, Modular timing relay, 0.7 A, 1 s..100 h, multifunction, solid state output, 24...240 V AC - Schneider Electric - Harmony, Modular timing relay, 0.7 A, 1 s..100 h, multifunction, solid state output, 24...240 V AC - Schneider Electric - 3
RE17LMBM - Harmony, Modular timing relay, 0.7 A, 1 s..100 h, multifunction, solid state output, 24...240 V AC - Schneider Electric
47,15 €
47,15 € incl. VAT
Text About:
Harmony, Modular timing relay, 0.7 A, 1 s..100 h, multifunction, solid state output, 24...240 V AC - Schneider Electric
47,15 €
SPECIFICATIONS
Main
component name RE17L
Complementary
maximum output current 20 A
compatibility code RE17
[ics] rated service breaking capacity 0.5 A AC conforming to UL
0.7 A AC at 20 °C
Control type Selector switch front panel
Product certifications GL
cULus
CSA
maximum leakage current 5 mA
Product or component type Multifunction relay
tightening torque 0.6…1 N.m conforming to IEC 60947-1
[uimp] rated impulse withstand voltage 5 kV during 1.2/50 µs
[us] rated supply voltage 24...240 V AC 50/60 Hz
maximum voltage drop <4 V 3-wire
<8 V 2-wire
Connections - terminals Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end
Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end
Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end
Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
minimum switching current 10 mA
marking CE
reset time 350 ms on de-energisation typical
safety reliability data MTTFd = 353.8 years
B10d = 320000
Derating factor 5 mA/°C
width (w) 17.5 mm
On-load factor 100 %
Creepage distance 4 kV/3 conforming to IEC 60664-1
temperature drift +/- 0.05 %/°C
Net weight 0.068 kg
voltage drift +/- 0.2 %/V
Discrete output type Solid state
functionality Multifunction
Immunity to microbreaks 20 ms
Mounting support 35 mm DIN rail conforming to EN/IEC 60715
electrical durability 100000000 cycles
operating frequency 10 Hz
repeat accuracy +/- 0.5 % conforming to IEC 61812-1
control signal pulse width 0.05 s typical
Housing material Self-extinguishing
Power consumption in va 0…3 VA at 240 V AC
Time delay range 1...10 s
6...60 s
6...60 min
1...10 h
10...100 h
1...10 min
0.1...1 s
mounting position Any position in relation to normal vertical mounting plane
maximum power consumption in w 1.5 W at 240 V DC
Maximum switching voltage 250 V AC
dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Supply frequency 50...60 Hz +/- 5 %
Power on delay 100 ms
Release of input voltage 8 V
Nominal output current 0.7 A
Setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Time delay type A, Ac, At, B, Bw, C, D, Di, H, Ht
Voltage range 0.85...1.1 Us
Environment
Ambient air temp for storage/transportation -30…60 °C
ip degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
Range of product Harmony Timer Relays
ambient air temperature for operation -20…60 °C
electromagnetic compatibility Electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2
Electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5
Conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11
Voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11
Conducted and radiated emissions: , class B, conforming to EN 55022
standards 2004/108/EC
EN 61000-6-2
IEC 61812-1
EN 61000-6-4
EN 61000-6-1
2006/95/EC
EN 61000-6-3
relative humidity 93 % without condensation conforming to IEC 60068-2-30
vibration resistance 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1