All categories
Compare Cart

RE17LCBMS - Modular timing relay, Harmony, 0.7A, 1s..100h, off delay, solid state output, spring terminals, 24...240V AC - Schneider Electric

Expected in 2-4 weeks
RE17LCBMS - Modular timing relay, Harmony, 0.7A, 1s..100h, off delay, solid state output, spring terminals, 24...240V AC - Schneider Electric - Modular timing relay, Harmony, 0.7A, 1s..100h, off delay, solid state output, spring terminals, 24...240V AC - Schneider Electric - 0
RE17LCBMS - Modular timing relay, Harmony, 0.7A, 1s..100h, off delay, solid state output, spring terminals, 24...240V AC - Schneider Electric - Modular timing relay, Harmony, 0.7A, 1s..100h, off delay, solid state output, spring terminals, 24...240V AC - Schneider Electric - 1
RE17LCBMS - Modular timing relay, Harmony, 0.7A, 1s..100h, off delay, solid state output, spring terminals, 24...240V AC - Schneider Electric - Modular timing relay, Harmony, 0.7A, 1s..100h, off delay, solid state output, spring terminals, 24...240V AC - Schneider Electric - 2
RE17LCBMS - Modular timing relay, Harmony, 0.7A, 1s..100h, off delay, solid state output, spring terminals, 24...240V AC - Schneider Electric - Modular timing relay, Harmony, 0.7A, 1s..100h, off delay, solid state output, spring terminals, 24...240V AC - Schneider Electric - 3
RE17LCBMS - Modular timing relay, Harmony, 0.7A, 1s..100h, off delay, solid state output, spring terminals, 24...240V AC - Schneider Electric - Modular timing relay, Harmony, 0.7A, 1s..100h, off delay, solid state output, spring terminals, 24...240V AC - Schneider Electric - 4
RE17LCBMS - Modular timing relay, Harmony, 0.7A, 1s..100h, off delay, solid state output, spring terminals, 24...240V AC - Schneider Electric
61,72 € excl. VAT
75,30 € incl. VAT
Text About:
Modular timing relay, Harmony, 0.7A, 1s..100h, off delay, solid state output, spring terminals, 24...240V AC - Schneider Electric
75,30 €
SPECIFICATIONS
Main
component name RE17L
Complementary
maximum output current 20 A
compatibility code RE17
[ics] rated service breaking capacity 0.5 A AC conforming to UL
0.7 A AC at 20 °C
Control type Selector switch front panel
Product certifications CSA
cULus
DNV-GL
EAC
Handle front plate colour 90 mm
maximum leakage current 5 mA
Product or component type Single function relay
[uimp] rated impulse withstand voltage 5 kV during 1.2/50 µs
[us] rated supply voltage 24...240 V AC 50/60 Hz
maximum voltage drop <4 V 3-wire
<8 V 2-wire
Connections - terminals Spring terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid without cable end
Spring terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible without cable end
minimum switching current 10 mA
marking CE
reset time 350 ms on de-energisation typical
safety reliability data MTTFd = 353.8 years
B10d = 320000
Derating factor 5 mA/°C
width (w) 17.5 mm
On-load factor 100 %
Creepage distance 4 kV/3 conforming to IEC 60664-1
temperature drift +/- 0.05 %/°C
Net weight 0.05 kg
voltage drift +/- 0.2 %/V
Discrete output type Solid state
functionality Off-delay timing
Immunity to microbreaks 20 ms
Mounting support 35 mm DIN rail conforming to EN/IEC 60715
depth 72 mm
electrical durability 100000000 cycles
operating frequency 10 Hz
repeat accuracy +/- 0.5 % conforming to IEC 61812-1
control signal pulse width 0.05 s typical
Housing material Self-extinguishing
Power consumption in va 0…3 VA at 240 V AC
Time delay range 10...100 h
6...60 s
6...60 min
1...10 h
1...10 s
1...10 min
0.1...1 s
mounting position Any position in relation to normal vertical mounting plane
Maximum switching voltage 250 V AC
dielectric strength 2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Supply frequency 50...60 Hz +/- 5 %
Power on delay 100 ms
Release of input voltage 7 V
Nominal output current 0.7 A
Setting accuracy of time delay +/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Time delay type C
Voltage range 0.85...1.1 Us
Environment
Ambient air temp for storage/transportation -30…60 °C
ip degree of protection IP20 (terminal block) conforming to IEC 60529
IP40 (housing) conforming to IEC 60529
IP50 (front panel) conforming to IEC 60529
Range of product Harmony Timer Relays
ambient air temperature for operation -20…60 °C
electromagnetic compatibility Electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2
Electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4
Electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5
1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5
Conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6
Voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11
Voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11
Conducted and radiated emissions: , class B, conforming to EN 55022
standards 2004/108/EC
EN 61000-6-3
2006/95/EC
EN 61000-6-2
IEC 61812-1
EN 61000-6-4
EN 61000-6-1
relative humidity 93 % without condensation conforming to IEC 60068-2-30
vibration resistance 20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
insulation resistance 100 MOhm at 500 V DC conforming to IEC 60664-1
Recently viewed
61,72 € excl. VAT
75,30 € incl. VAT
Expected in 2-4 weeks