Complementary
																					
												power quality analysis
												conforming to EN 50160: 2010 compliance report
 conforming to IEEE 519: 2014 compliance report
 conforming to IEC 61000-4-30: class S power quality measurement
 up to the 63rd harmonic
 harmonic distortion
 waveform capture
 voltage sag and swell detection
 programmablity (logic and math functions)
 conforming to IEC 62586 power quality monitoring
											
                            
																					
												[in] rated current
												5 A
1 A
10 A
											
                            
																					
												Communication network type
												IPv6 (internet protocol)
											
                            
																					
												memory capacity
												512 MB
											
                            
																					
												Product certifications
												CE
CULus
N998
											
                            
																					
												Communication port support
												ETHERNET
Screw terminal block: RS485
											
                            
																					
												Handle front plate colour
												90.5 mm
											
                            
																					
												Product or component type
												Power meter
											
                            
																					
												accuracy class
												Class 0.2S active energy conforming to IEC 62053-22
Class 0.2 active energy conforming to ANSI C12.20
Class 0.2 active power conforming to IEC 61557-12
Class 0.5S reactive energy conforming to IEC 62053-24
Class 0.5 power factor conforming to IEC 61557-12
Class 0.2 voltage conforming to IEC 61557-12
Class 0.2 current conforming to IEC 61557-12
											
                            
																					
												Device application
												Power monitoring
WAGES metering
											
                            
																					
												Installation category
												III
											
                            
																					
												type of measurement
												Current
Voltage
Frequency
Active and reactive power total
Apparent power total
Power factor total
Active and reactive power per phase, rms
Apparent power per phase, rms
Power factor per phase, rms
											
                            
																					
												Analogue input type
												Voltage (impedance 5 MOhm)
Current (impedance 0.3 mOhm)
											
                            
																					
												cybersecurity
												Enable/disable communication ports
Robust security logs
Port hardening
Password protection
Syslog protocol support
											
                            
																					
												Data recording
												Harmonics logs
Waveform logs
Trending/forecasting
Event logs
Alarm logs
Data logs
Sequence of event recording
Sag and swell logs
Min/max of instantaneous values
Time stamping
GPS synchronisation
											
                            
																					
												information displayed
												Voltage
Current
Frequency
Power
Energy consumption
Harmonic distortion
											
                            
																					
												width (w)
												90.5 mm
											
                            
																					
												network frequency
												50 Hz
60 Hz
											
                            
																					
												number of outputs
												1 pulse
											
                            
																					
												Mounting mode
												Clip-on
Flush-mounted
											
                            
																					
												Net weight
												528 g
											
                            
																					
												Communication service
												RSTP support
DHCP
SMTP e-mail notification
NTP time synchronization
SNMP
PTP time synchronization
											
                            
																					
												frequency measurement range
												42…69 Hz
											
                            
																					
												measurement accuracy
												Current +/- 0.1 %
Voltage +/- 0.1 %
Active energy +/- 0.2 %
											
                            
																					
												communication port protocol
												Modbus RTU at 115 kbauds - 2-wire
ION at 115 kbauds - 2-wire
DNP3
IEC 61850
Modbus TCP/IP
Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s
RSTP 801.1d 2004
											
                            
																					
												Display type
												Remote LCD display
											
                            
																					
												Mounting support
												DIN rail meter device
Framework remote display
											
                            
																					
												depth
												90.8 mm
											
                            
																					
												Number of inputs
												3 digital 30 V AC
3 digital 60 V DC
											
                            
																					
												Power consumption in w
												17 W
											
                            
																					
												sampling rate
												256 samples/cycle
											
                            
																					
												display resolution
												320 x 240 pixels QVGA
											
                            
																					
												Provided equipment
												Remote display
											
                            
																					
												supply voltage
												20...60 V DC +/- 10 %
											
                            
																					
												Safety construction
												III400…690 V conforming to IEC 61010-1:ed. 3
III400…690 V conforming to EN 61010-1:ed. 3
III347…600 V conforming to UL 61010-1:ed. 3
III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
											
                            
																					
												Poles description
												3P
1P + N
3P + N
											
                            
																					
												Web services
												Customizable home page
File upload/download via FTP
File upload/download via SFTP
Web server
Alarm notification by e-mail
Viewing of captured waveform (FTP)
Viewing of captured waveform (web)
HTTPS server
											
                            
																			 
																	
										Environment
																					
												Ambient air temp for storage/transportation
												-40…85 °C
											
                            
																					
												ip degree of protection
												IP30 conforming to IEC 60529
											
                            
																					
												operating altitude
												3000 m
											
                            
																					
												ambient air temperature for operation
												-25…70 °C
											
                            
																					
												electromagnetic compatibility
												Electrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Immunity to impulse waves conforming to IEC 61000-4-12
Conducted and radiated emissions conforming to EN 55022
Conducted and radiated emissions conforming to EN 55011
Conducted and radiated emissions conforming to FCC part 15
Conducted and radiated emissions conforming to ICES-003
Conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579
Surge withstand conforming to IEEE C37.90.1
											
                            
																					
												standards
												IEC 61557-12
IEC 62052-11
IEC 62053-24
IEC 62053-22
IEEE 1588
IEC 62586-2
IEC 61326-1
											
                            
																					
												relative humidity
												5…95 %