All categories
Compare Cart

METSEPM8210 - PowerLogic PM8000 PM8210 LV DC Panel mount meter intermediate metering - Schneider Electric

Expected in 2-4 weeks
METSEPM8210 - PowerLogic PM8000 PM8210 LV DC Panel mount meter intermediate metering - Schneider Electric - PowerLogic PM8000 PM8210 LV DC Panel mount meter intermediate metering - Schneider Electric - 0
METSEPM8210 - PowerLogic PM8000 PM8210 LV DC Panel mount meter intermediate metering - Schneider Electric
2 025,59 € excl. VAT
2 471,22 € incl. VAT
Text About:
PowerLogic PM8000 PM8210 LV DC Panel mount meter intermediate metering - Schneider Electric
2 471,22 €
SPECIFICATIONS
Main
Device short name PM8210
Measurement current 50…10000 mA
Range PowerLogic
Product Name PowerLogic PM8000
Measurement voltage 57…400 V AC 42...69 Hz between phase and neutral
100…690 V AC 42...69 Hz between phases
Complementary
power quality analysis conforming to EN 50160: 2010 compliance report
conforming to IEEE 519: 2014 compliance report
conforming to IEC 61000-4-30: class S power quality measurement
up to the 63rd harmonic
harmonic distortion
waveform capture
voltage sag and swell detection
programmablity (logic and math functions)
conforming to IEC 62586 power quality monitoring
[in] rated current 10 A
5 A
1 A
Communication network type IPv6 (internet protocol)
memory capacity 512 MB
Product certifications CE
CULus
N998
Communication port support ETHERNET
Screw terminal block: RS485
Handle front plate colour 96 mm
Product or component type Power meter
accuracy class Class 0.2S active energy conforming to IEC 62053-22
Class 0.2 active energy conforming to ANSI C12.20
Class 0.2 active power conforming to IEC 61557-12
Class 0.5S reactive energy conforming to IEC 62053-24
Class 0.5 power factor conforming to IEC 61557-12
Class 0.2 voltage conforming to IEC 61557-12
Class 0.2 current conforming to IEC 61557-12
Device application Power monitoring
WAGES metering
Installation category III
type of measurement Current
Voltage
Frequency
Active and reactive power total
Apparent power total
Power factor total
Active and reactive power per phase, rms
Apparent power per phase, rms
Power factor per phase, rms
Analogue input type Voltage (impedance 5 MOhm)
Current (impedance 0.3 mOhm)
cybersecurity Syslog protocol support
Password protection
Port hardening
Enable/disable communication ports
Robust security logs
Data recording Data logs
Harmonics logs
Waveform logs
Min/max of instantaneous values
Trending/forecasting
Sag and swell logs
Sequence of event recording
GPS synchronisation
Alarm logs
Event logs
Time stamping
information displayed Voltage
Current
Frequency
Power
Energy consumption
Harmonic distortion
width (w) 96 mm
network frequency 60 Hz
50 Hz
number of outputs 1 pulse
Mounting mode Flush-mounted
Net weight 581 g
Communication service NTP time synchronization
SMTP e-mail notification
DHCP
RSTP support
SNMP
PTP time synchronization
frequency measurement range 42…69 Hz
measurement accuracy Current +/- 0.1 %
Voltage +/- 0.1 %
Active energy +/- 0.2 %
communication port protocol Modbus RTU at 115 kbauds - 2-wire
ION at 115 kbauds - 2-wire
DNP3
IEC 61850
Modbus TCP/IP
Ethernet Modbus TCP/IP daisy chain at 10/100 Mbit/s
RSTP 801.1d 2004
Display type Colour TFT LCD
Mounting support Framework
depth 77.5 mm
Number of inputs 3 digital 30 V AC
3 digital 60 V DC
Power consumption in w 17 W
sampling rate 256 samples/cycle
display resolution 320 x 240 pixels QVGA
supply voltage 20...60 V DC +/- 10 %
Safety construction III400…690 V conforming to IEC 61010-1:ed. 3
III400…690 V conforming to EN 61010-1:ed. 3
III347…600 V conforming to UL 61010-1:ed. 3
III347…600 V conforming to CSA C22.2 No 61010-1:ed. 3
Poles description 3P
1P + N
3P + N
Web services Customizable home page
File upload/download via FTP
File upload/download via SFTP
Web server
Alarm notification by e-mail
Viewing of captured waveform (FTP)
Viewing of captured waveform (web)
HTTPS server
Environment
Ambient air temp for storage/transportation -40…85 °C
ip degree of protection IP54 front: conforming to IEC 60529
IP30 body: conforming to IEC 60529
operating altitude 3000 m
ambient air temperature for operation -25…70 °C
electromagnetic compatibility Electrostatic discharge conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
Surge immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Magnetic field at power frequency conforming to IEC 61000-4-8
Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Immunity to impulse waves conforming to IEC 61000-4-12
Conducted and radiated emissions conforming to EN 55022
Conducted and radiated emissions conforming to EN 55011
Conducted and radiated emissions conforming to FCC part 15
Conducted and radiated emissions conforming to ICES-003
Conducted RF disturbances (2...150 Hz) conforming to CLC/TR 50579
Surge withstand conforming to IEEE C37.90.1
standards IEC 62052-11
IEC 61557-12
IEC 62053-22
IEC 62053-24
IEEE 1588
IEC 62586-2
IEC 61326-1
relative humidity 5…95 %
Recently viewed
2 025,59 € excl. VAT
2 471,22 € incl. VAT
Expected in 2-4 weeks