All categories
Compare Cart

METSEPM5350 - PM5350 Power & Energy meter with THD, alarming - Schneider Electric

Expected in 2-4 weeks
METSEPM5350 - PM5350 Power & Energy meter with THD, alarming - Schneider Electric - PM5350 Power & Energy meter with THD, alarming - Schneider Electric - 0
METSEPM5350 - PM5350 Power & Energy meter with THD, alarming - Schneider Electric
625,23 € excl. VAT
762,78 € incl. VAT
Text About:
PM5350 Power & Energy meter with THD, alarming - Schneider Electric
762,78 €
SPECIFICATIONS
Main
Device short name PM5350
Measurement current 5…9000 mA
Range PowerLogic
Product Name PowerLogic PM5350
Measurement voltage 35…760 V AC 45...65 Hz phase to phase
20…400 V AC phase to neutral
Complementary
power quality analysis total demand distortion
total harmonic distortion
[in] rated current 5 A
1 A
maximum power consumption in va 11.9 VA
Product certifications CE
CULus
Communication port support Terminal block: RS485
Handle front plate colour 96 mm
Product or component type Power meter
accuracy class Class 0.5S active energy conforming to IEC 62053-22
Class 0.5 active energy conforming to IEC 61557-12
Class 3 reactive energy conforming to IEC 62053-23
Class 2 reactive energy conforming to IEC 61557-12
Class 0.5 power conforming to IEC 61557-12
Connections - terminals Voltage circuit: screw terminal block4
Control circuit: screw terminal block2
Current transformer: screw terminal block6
Input/output circuit: screw terminal block6
Relay output: screw terminal block4
Ethernet network: RJ45 connector
Device application Power monitoring
type of measurement Current
Voltage
Frequency
Power factor
Energy
Phase angle
Apparent power
Active power
Reactive power
Analogue input type Current 0.05...9 A (impedance <= 0.3 mOhm)
Voltage (impedance 10 MOhm)
Data recording Min/max of instantaneous values
Alarms
information displayed Tariff (4)
width (w) 96 mm
network frequency 50 Hz
60 Hz
number of outputs 2 relay
Mounting mode Flush-mounted
Net weight 0.25 kg
frequency measurement range 45…70 Hz
measurement accuracy Current +/- 0.5 %
Voltage +/- 0.5 %
Frequency +/- 0.05 %
Power factor +/- 0.5
Active energy +/- 0.5 %
Reactive energy +/- 2 %
Active power +/- 0.5 %
Apparent power +/- 0.5 %
Apparent energy +/- 0.5 %
Reactive power +/- 2 %
communication port protocol JBUS
Modbus RTU and ASCII at 9.6, 19.2 and 38.4 kbauds
Display type Monochrome graphic LCD
depth 44 mm
Network type 1P + N
3P + N
3P
Number of inputs 4 digital
Pollution degree 2
Type of installation Indoor installation
sampling rate 32 samples/cycle
display resolution 6 lines
supply voltage 90...450 V AC 45...65 Hz
100...300 V DC
Ride-through time 100 ms 120 V AC typical
400 ms 230 V AC typical
50 ms 125 V DC typical
Environment
Ambient air temp for storage/transportation -40…85 °C
ip degree of protection IP30 rear: conforming to IEC 60529
IP54 display: conforming to IEC 60529
operating altitude <= 3000 m
ambient air temperature for operation -25…70 °C meter
-20…70 °C display
-25…-20 °C (with reduced performance) display
electromagnetic compatibility Limitation of voltage changes, voltage fluctuations and flicker in low-voltage conforming to IEC 61000-3-3
Electrostatic discharge conforming to IEC 61000-4-2
Susceptibility to electromagnetic fields conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test conforming to IEC 61000-4-4
1.2/50 µs shock waves immunity test conforming to IEC 61000-4-5
Conducted RF disturbances conforming to IEC 61000-4-6
Immunity to impulse waves conforming to IEC 61000-4-12
Conducted and radiated emissions class A conforming to EN 55011
Limits for harmonic current emissions conforming to IEC 61000-3-2
overvoltage category III
standards IEC 61010-1
relative humidity 5…95 % at 50 °C non-condensing
Recently viewed
625,23 € excl. VAT
762,78 € incl. VAT
Expected in 2-4 weeks