SPECIFICATIONS
Main
Range PowerLogic
name of the device PM5310
type of product or equipment Centrale de mesure
Product Name PowerLogic PM5000
Complementary
power quality analysis jusqu'à 31ème harmonique
[in] rated current 1 A
5 A
application Multi-tarif
Surveillance de puissance
maximum power consumption in va 11 VA à 415 V
memory capacity 256 kB
Handle front plate colour 96 mm
accuracy class Classe 0,5S énergie active se conformer à CEI 62053-22
data logging Rapports des événements
Nombre min./maxi de valeurs instantanées
Journaux d'alarme
Rapports de données
Horodatage
Journaux de maintenance
product weight 430 g
measuring current 5…8500 mA
mode d'installation Suspendu
type of measurement Courant
Tension
Fréquence
Facteur de puissance
Énergie
Puissance active et réactive
connection mode Circuit de tension: bornier à vis4
Télécommande: bornier à vis2
Transformateur de courant: bornier à vis6
Circuit d'entrée/de sortie: bornier à vis6
Sortie relais: bornier à vis4
Réseau Ethernet: connecteur RJ45
information displayed Tarif (4)
width (w) 96 mm
network frequency 50 Hz
60 Hz
number of entries 2 numérique
number of outputs 2 logique
frequency measurement range 45…65 Hz
measurement accuracy Énergie active +/- 0,5 %
Énergie réactive +/- 2 %
Puissance active +/- 0,5 %
Puissance apparente +/- 0,5 %
Fréquence +/- 0,05 %
Facteur de puissance +/- 0.5
Courant +/- 0,5 %
Tension +/- 0,5 %
Énergie apparente +/- 0,5 %
Puissance réactive +/- 2 %
communication port protocol Modbus RTU et ASCII à 9,6, 19,2 et 38,4 kbauds pair / impair ou aucun - 2 fils, isolation 2500 V
JBUS
depth 72 mm
mounting bracket Ossature
Network type 1P + N
3P
3P + N
support port de communication RS485
sampling rate 64 échantillons/cycle
display resolution 128 x 128 pixels
measuring voltage 35…760 V CA 45...65 Hz entre phases
20…440 V CA 45...65 Hz entre phase et neutre
type of display Monochrome graphic LCD
supply voltage 90...450 V CA 45...65 Hz
100…300 V CC
travel time 80 ms 120 V CA typique
100 ms 230 V CA typique
100 ms 415 V CA typique
50 ms 125 V CC typique
analog input type tension (impédance 5 MOhm)
courant (impédance <= 0.3 mOhm)
Environment
degree of pollution 2
ip degree of protection IP54 Affichage: se conformer à CEI 60529
IP30 arrière: se conformer à CEI 60529
operating altitude 2000 m CAT III
3000 m CAT II
product certificates CE se conformer à CEI 61010-1
CULus se conformer à UL 61010-1
electromagnetic compatibility Émissions transmises par conduction et rayonnéesclasse A se conformer à EN 55011
Limitation d'émission de courant harmoniqueclasse A se conformer à CEI 61000-3-2
Immunité aux perturbations transmises par conduction - niveau de test : 150 kHz...80 MHzniveau 3 se conformer à CEI 61000-4-6
Test d'immunité aux baisses et aux interruptions de tensionniveau 4 se conformer à CEI 61000-4-11
Perturbations RF transmises par conductionniveau 3 se conformer à CEI 61000-4-6
Champ magnétique à la fréquence d'alimentationniveau 4 se conformer à CEI 61000-4-8
Émissions transmises par conduction et rayonnéesclasse B se conformer à EN 55022
Limitation aux Creux et sauts de tension se conformer à CEI 61000-3-3
Décharge électrostatique - niveau de test : 8 kVniveau 4 se conformer à CEI 6100-4-11
Test d'immunité aux champs électromagnétiques radio-fréquences rayonnés se conformer à CEI 61000-4-3
Test d'immunité aux transitoires électriques rapidesniveau 4 se conformer à CEI 61000-4-4
Test d’immunité aux surtensionsniveau 4 se conformer à CEI 61000-4-5
Test d'immunité aux baisses et aux interruptions de tension se conformer à CEI 61000-4-11
standards EN 50470-3
CEI 62053-24
CEI 60529
EN 50470-1
UL 61010-1
CEI 62053-22
CEI 61557-12
relative humidity 5…95 % à 50 °C sans condensation
operating temperature -25…70 °C compteur
-20…70 °C Affichage
-25…-20 °C (with reduced performance) Affichage