All categories
Compare Cart

MCN202 - MCN202 - Hager

Expected in 2-4 weeks
MCN202 - MCN202 - Hager - MCN202 - Hager - 0
MCN202 - MCN202 - Hager
16,83 € excl. VAT
20,54 € incl. VAT
Text About:
MCN202 - Hager
20,54 €
SPECIFICATIONS
Additional Information
curve C
type of pole 2 P
Main
Number of modules 2
rated operational voltage ue 400 V
Number of protected poles 2
rated short circuit breaking capacity icn ac according iec60898-1 6 kA
type of supply voltage AC
Complementary
air humidity protection for all climates
bottom connection alignement for modular devices Aligned terminal
concurrently switching n-neutral No
connection cross section of access and exit with screws, for flexible conductor 1 / 25 mm²
connection cross-sect. flexible conductor 1 / 25mm²
correction factor of magnetic tripping with 100 hz 1.1
correction factor of rating current for 2 devices placed side-by-side 1
depth of installed product 70 mm
electric endurance in number of cycles 4000
power loss per pole at in 1.4 W
rating current -10°c 2.5 A
search words Circuit breaker;Machine;Built-in machine;Built-in device;Installation machine;Rail mounted device;Automatic cutout;Controller circuit-breaker;Built-in distribution unit;Automatic plug-in fuse
[in] rated current 2 A
breaking capacity on 1 pole for it 400v nf 60947-2 3 kA
connection cross-sect. rigid cable 1 / 35mm²
correction factor of magnetic tripping with 200 hz 1.2
correction factor of rating current for 3 devices placed side-by-side 0.95
degree of pollution according to iec 60664 / iec 60947-2 2
height of installed product 83 mm
magnetic regulating currrent 5 / 10 In
number of mechanical operations 20000
rating current -15°c 2.6 A
top connection alignement for modular devices Aligned terminal
total power loss under in 2.7 W
class of energy limitation i²t 3
correction factor of magnetic tripping with 400 hz 1.5
correction factor of rating current for 4 and 5 devices placed side-by-side 0.9
min/maxi threshold value of the ac thermal operation 1.13 / 1.45 In
rating current -20°c 2.6 A
type of connection with screw
width of installed product 35 mm
connection cross-section of input and output with screws, for massive conductors 1 / 35 mm²
correction factor of magnetic tripping with 60 hz 1
correction factor of rating current for 6 devices placed side-by-side 0.85
min/maxi threshold value of the dc magnetic operation 7 / 15 In
rating current -25°c 2.7 A
storage/transport temperature -25…80 °C
tightening torque 2,8Nm
type of bottom connection for modular devices BIconnect
min/maxi threshold value of the dc thermal operation 1.13 / 1.45 In
rated short circuit breaking capacity icn under 400v ac according iec60898-1 6 kA
rating current -5°c 2.5 A
Rated insulation voltage 500 V
rating current 0°c 2.4 A
type of top connection for modular devices with screw
rated service breaking capacity ics ac according iec 60898-1 6 kA
rated ultimate short-circuit breaking capacity icu under 400v ac iec 60947-2 10 kA
rating current 10°c 2.3 A
rated ultimate short-circuit breaking capacity icu under 415v ac iec 60947-2 10 kA
rating current 15°c 2.2 A
rating current 20°c 2.1 A
rating current 25°c 2.1 A
rating current 30°c 2 A
rating current 35°c 1.9 A
rating current 40°c 1.9 A
rating current 45°c 1.8 A
rating current 50°c 1.7 A
rating current 55°c 1.6 A
rating current 5°c 2.3 A
frequency 50 to 60 Hz
rating current 60°c 1.5 A
rating current 65°c 1.4 A
rating current 70°c 1.3 A
rated impulse withstand voltage 4000 V
Poles description 2 P
Environment
altitude 2000 m
european directive weee concerned
protection index ip IP20
standard text EN 60898-1
operating temperature -25…70 °C
Recently viewed
16,83 € excl. VAT
20,54 € incl. VAT
Expected in 2-4 weeks