All categories
Compare Cart

MCN104 - MCN104 - Hager

Expected in 2-4 weeks
MCN104 - MCN104 - Hager - MCN104 - Hager - 0
MCN104 - MCN104 - Hager
6,35 € excl. VAT
7,75 € incl. VAT
Text About:
MCN104 - Hager
7,75 €
SPECIFICATIONS
Additional Information
curve C
type of pole 1 P
Main
Number of modules 1
rated operational voltage ue 230 / 400 V
Number of protected poles 1
rated short circuit breaking capacity icn ac according iec60898-1 6 kA
type of supply voltage AC
Complementary
air humidity protection for all climates
bottom connection alignement for modular devices Aligned terminal
concurrently switching n-neutral No
connection cross section of access and exit with screws, for flexible conductor 1 / 25 mm²
connection cross-sect. flexible conductor 1 / 25mm²
correction factor of magnetic tripping with 100 hz 1.1
correction factor of rating current for 2 devices placed side-by-side 1
depth of installed product 70 mm
electric endurance in number of cycles 4000
power loss per pole at in 1.9 W
rating current -10°c 4.9 A
search words Circuit breaker;Machine;Built-in machine;Built-in device;Installation machine;Rail mounted device;Automatic cutout;Controller circuit-breaker;Built-in distribution unit;Automatic plug-in fuse
[in] rated current 4 A
breaking capacity on 1 pole for it 400v nf 60947-2 3 kA
connection cross-sect. rigid cable 1 / 35mm²
correction factor of magnetic tripping with 200 hz 1.2
correction factor of rating current for 3 devices placed side-by-side 0.95
degree of pollution according to iec 60664 / iec 60947-2 2
height of installed product 83 mm
magnetic regulating currrent 5 / 10 In
number of mechanical operations 20000
rating current -15°c 5 A
top connection alignement for modular devices Aligned terminal
total power loss under in 1.9 W
class of energy limitation i²t 3
correction factor of magnetic tripping with 400 hz 1.5
correction factor of rating current for 4 and 5 devices placed side-by-side 0.9
min/maxi threshold value of the ac thermal operation 1.13 / 1.45 In
rating current -20°c 5.1 A
type of connection with screw
width of installed product 17.5 mm
connection cross-section of input and output with screws, for massive conductors 1 / 35 mm²
correction factor of magnetic tripping with 60 hz 1
correction factor of rating current for 6 devices placed side-by-side 0.85
min/maxi threshold value of the dc magnetic operation 7 / 15 In
rating current -25°c 5.2 A
storage/transport temperature -25…80 °C
tightening torque 2,8Nm
type of bottom connection for modular devices BIconnect
min/maxi threshold value of the dc thermal operation 1.13 / 1.45 In
rated ultimate short-circuit breaking capacity icu under 230v ac iec 60947-2 10 kA
rating current -5°c 4.8 A
Rated insulation voltage 500 V
rated ultimate short-circuit breaking capacity icu under 240v ac iec 60947-2 10 kA
rating current 0°c 4.7 A
type of top connection for modular devices with screw
rated service breaking capacity ics ac according iec 60898-1 6 kA
rating current 10°c 4.5 A
rated short circuit breaking capacity icn under 230v ac according iec60898-1 6 kA
rating current 15°c 4.4 A
rating current 20°c 4.2 A
rating current 25°c 4.1 A
rating current 30°c 4 A
rating current 35°c 3.9 A
rating current 40°c 3.8 A
rating current 45°c 3.6 A
rating current 50°c 3.5 A
rating current 55°c 3.3 A
rating current 5°c 4.6 A
frequency 50 to 60 Hz
rating current 60°c 3.2 A
rating current 65°c 3 A
rating current 70°c 2.9 A
rated impulse withstand voltage 4000 V
Poles description 1 P
Environment
altitude 2000 m
european directive weee concerned
protection index ip IP20
standard text EN 60898-1
operating temperature -25…70 °C
Recently viewed
6,35 € excl. VAT
7,75 € incl. VAT
Expected in 2-4 weeks