SPECIFICATIONS
Additional Information
curve B
type of pole 2 P
Main
Number of modules 2
rated operational voltage ue 400 V
Number of protected poles 2
rated short circuit breaking capacity icn ac according iec60898-1 6 kA
type of supply voltage AC
Complementary
air humidity protection for all climates
bottom connection alignement for modular devices Aligned terminal
bottom removability for modular devices No
concurrently switching n-neutral No
connection cross section of access and exit with screws, for flexible conductor 1 / 25 mm²
connection cross-sect. flexible conductor 1 / 25mm²
correction factor of magnetic tripping with 100 hz 1.1
correction factor of rating current for 2 devices placed side-by-side 1
depth of installed product 70 mm
electric endurance in number of cycles 4000
power loss per pole at in 4.25 W
rating current -10°c 61.1 A
[in] rated current 50 A
breaking capacity on 1 pole for it 400v nf 60947-2 3 kA
connection cross-sect. rigid cable 1 / 35mm²
correction factor of magnetic tripping with 200 hz 1.2
correction factor of rating current for 3 devices placed side-by-side 0.95
degree of pollution according to iec 60664 / iec 60947-2 2
height of installed product 83 mm
magnetic regulating currrent 3 / 5 In
number of mechanical operations 20000
rating current -15°c 62.3 A
top connection alignement for modular devices Aligned terminal
total power loss under in 8.4 W
class of energy limitation i²t 3
correction factor of magnetic tripping with 400 hz 1.5
correction factor of rating current for 4 and 5 devices placed side-by-side 0.9
min/maxi threshold value of the ac thermal operation 1.13 / 1.45 In
rating current -20°c 63.5 A
top removability for modular devices No
type of connection with screw
width of installed product 35 mm
connection cross-section of input and output with screws, for massive conductors 1 / 35 mm²
correction factor of magnetic tripping with 60 hz 1
correction factor of rating current for 6 devices placed side-by-side 0.85
min/maxi threshold value of the dc magnetic operation 4 / 7 In
rating current -25°c 64.7 A
storage/transport temperature -25…80 °C
tightening torque 2,8Nm
type of bottom connection for modular devices BIconnect
min/maxi threshold value of the dc thermal operation 1.13 / 1.45 In
rated short circuit breaking capacity icn under 400v ac according iec60898-1 6 kA
rated ultimate short-circuit breaking capacity icu under 230v ac iec 60947-2 10 kA
rating current -5°c 59.9 A
type of bottom rail clip for modular devices metallic
Rated insulation voltage 500 V
rating current 0°c 58.7 A
type of top connection for modular devices with screw
rated service breaking capacity ics ac according iec 60898-1 6 kA
rating current 10°c 56.1 A
type of top rail clip for modular devices NA
rated ultimate short-circuit breaking capacity icu under 415v ac iec 60947-2 10 kA
rating current 15°c 54.7 A
rating current 20°c 53.4 A
rating current 25°c 52 A
rating current 30°c 50 A
rating current 35°c 48.8 A
rating current 40°c 47.7 A
rating current 45°c 46.5 A
rating current 50°c 45.3 A
rating current 55°c 44.1 A
rating current 5°c 57.4 A
frequency 50 to 60 Hz
rating current 60°c 43 A
rating current 65°c 41.8 A
rating current 70°c 40.6 A
rated impulse withstand voltage 4000 V
Poles description 2 P
Environment
altitude 2000 m
european directive weee concerned
protection index ip IP20
standard text EN 60898-1
operating temperature -25…70 °C