SPECIFICATIONS
Main
Device short name GFP
Range Multi9
Earth-leakage protection class Type A-SI (Super Immunised)
Neutral position Left
Earth-leakage protection time delay Instantaneous
Earth-leakage sensitivity 26 mA conforming to UL 1053
30 mA conforming to EN/IEC 61008-1
Product Name Multi9 GFP
[ui] rated insulation voltage 440 V AC 50/60 Hz
Complementary
9 mm pitches 4
[in] rated current 40 A at 40 °C conforming to EN/IEC 61008-1
[ue] rated operational voltage 480Y/277 V AC 60 Hz
240/415 V AC 50 Hz
[ics] rated service breaking capacity Idm 1500 A conforming to EN/IEC 61008-1
Control type Toggle
Product certifications IEC
UL
Handle front plate colour 81 mm
Product or component type Residual current circuit breaker (RCCB)
tightening torque 3.5 N.m top or bottom
[uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 61008-1
Connections - terminals Tunnel type terminals (top or bottom) 1…25 mm² (AWG 18...AWG 3) - flexible
Tunnel type terminals (top or bottom) 1…35 mm² (AWG 18...AWG 2) - rigid
Tunnel type terminals (top or bottom) 1…25 mm² (AWG 18...AWG 3) - flexible with ferrule
Locking options description Padlocking in OFF position
Contact position indication Yes
Device application Distribution
width (w) 36 mm
network frequency 50/60 Hz
Colour Grey
Local signalling ON, OFF, fault trip
Mounting mode Clip-on
Net weight 0.22 kg
wire stripping length 14 mm for top or bottom connection
Mounting support DIN rail
depth 60 mm
mechanical durability 20000 cycles
Network type AC
Pollution degree 3
residual current tripping technology Voltage independent
Rated conditional short-circuit current Inc 10 kA 100 A gG
Poles description 2P
Utilisation category AC-23A conforming to EN/IEC 61008-1
Environment
Ambient air temp for storage/transportation -40…70 °C
ip degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
ambient air temperature for operation -25…60 °C
electromagnetic compatibility 8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61008-1
standards EN/IEC 61008-1
UL 1053
Tropicalisation 2 conforming to IEC 60068-1
relative humidity 95 % at 55 °C