All categories
Compare Cart

M9R11440 - Residual current circuit breaker (RCCB), Multi9 ID, 4P, 40A, AC type, 30mA - Schneider Electric

Expected in 2-4 weeks
M9R11440 - Residual current circuit breaker (RCCB), Multi9 ID, 4P, 40A, AC type, 30mA - Schneider Electric - Residual current circuit breaker (RCCB), Multi9 ID, 4P, 40A, AC type, 30mA - Schneider Electric - 0
M9R11440 - Residual current circuit breaker (RCCB), Multi9 ID, 4P, 40A, AC type, 30mA - Schneider Electric
83,59 € excl. VAT
101,98 € incl. VAT
Text About:
Residual current circuit breaker (RCCB), Multi9 ID, 4P, 40A, AC type, 30mA - Schneider Electric
101,98 €
SPECIFICATIONS
Main
Device short name ID
Range Multi9
Earth-leakage protection class Type AC
Neutral position Left
Earth-leakage protection time delay Instantaneous
Earth-leakage sensitivity 30 mA
Product Name Multi9 ID
[ui] rated insulation voltage 440 V AC 50 Hz conforming to EN/IEC 61008-1
Complementary
9 mm pitches 8
[in] rated current 40 A
[ue] rated operational voltage 380...415 V AC 50 Hz
[ics] rated service breaking capacity Idm 400 A conforming to EN/IEC 61008-1
Control type Toggle
Product certifications CE
Handle front plate colour 81 mm
Product or component type Residual current circuit breaker (RCCB)
tightening torque 3.5 N.m top or bottom
[uimp] rated impulse withstand voltage 6 kV conforming to EN/IEC 61008-1
Connections - terminals Tunnel type terminal (top or bottom) 1…35 mm² - rigid
Tunnel type terminal (top or bottom) 1…25 mm² - flexible
Tunnel type terminal (top or bottom) 3 cable(s) 16 mm² - rigid
Tunnel type terminal (top or bottom) 3 cable(s) 10 mm² - flexible
Tunnel type terminal (top or bottom) 1…25 mm² - flexible with ferrule
Locking options description Padlocking device
Contact position indication Yes
Device application Distribution
width (w) 72 mm
network frequency 50 Hz
Colour Grey
Local signalling ON, OFF, fault trip
Mounting mode Clip-on
Net weight 0.45 kg
wire stripping length 15 mm for top or bottom connection
Mounting support DIN rail
depth 73 mm
mechanical durability 20000 cycles
electrical durability 2000 cycles
Network type AC
Pollution degree 3
residual current tripping technology Voltage independent
Surge current 250 A
Rated conditional short-circuit current Inc 10 kA
Poles description 4P
Environment
Ambient air temp for storage/transportation -40…60 °C
ip degree of protection IP20 conforming to IEC 60529
IP40 (modular enclosure) conforming to IEC 60529
ambient air temperature for operation -5…40 °C
electromagnetic compatibility 8/20 µs impulse withstand, 250 A conforming to EN/IEC 61008-1
standards EN/IEC 61008-1
Tropicalisation 2 conforming to IEC 60068-1
relative humidity 95 % at 55 °C
Recently viewed
83,59 € excl. VAT
101,98 € incl. VAT
Expected in 2-4 weeks