Main
Device short name
LX1FL
Inductance of closed circuit
3.35 H
Range
TeSys
[uc] control circuit voltage
220...240 V AC 40...400 Hz
control circuit type
AC at 40...400 Hz
Complementary
product compatibility
LC1F630
LC1F1250
range compatibility
TeSys (TeSys F) LC1F contactor
Average resistance
25.5 Ohm inrush at 20 °C
730 Ohm holding at 20 °C
Product or component type
Contactor coil
Control circuit voltage limits
Operational: 0.85...1.1 Uc 40...400 Hz (at 55 °C)
Drop-out: 0.25...0.5 Uc 40...400 Hz (at 55 °C)
Heat dissipation
20 W at 40...400 Hz
Net weight
1.5 kg
Hold-in power consumption in va
22 VA 40...400 Hz cos phi 0.3 (at 20 °C)
Inrush power in va
1650 VA 40...400 Hz cos phi 0.9 (at 20 °C)
mechanical durability
5 Mcycles
Maximum operating rate
1200 cyc/h 55 °C
operating time
100...200 ms opening
40...80 ms closing
coil technology
Without built-in suppressor module
Environment
ambient air temperature for operation
-5…55 °C