SPECIFICATIONS
Main
Range Masterpact
sectioning ability Oui se conformer à CEI 60947-2
name of the device MTZ2 32 H2V
type of product or equipment Disjoncteur
Product Name MasterPacT MTZ2
[ui] rated insulation voltage 1000 V CA 50/60 Hz se conformer à CEI 60947-2
selectivity category Catégorie B
breaking capacity coding H2V
performance level 100 kA Icu à 220/415 V CA 50/60 Hz se conformer à CEI 60947-2
100 kA Icu à 440 V CA 50/60 Hz se conformer à CEI 60947-2
neutral pole position Gauche
Complementary
"no" connection 115 mm
[icm] rated short circuit making capacity 220 kA 220/415 V CA à 50/60 Hz
220 kA 440 V CA à 50/60 Hz
[in] rated operational current 3200 A à 40 °C
[ue] rated operational voltage 440 V CA 50/60 Hz se conformer à CEI 60947-2
application Protection
[ics] rated service breaking capacity 100 kA à 220/415 V CA 50/60 Hz se conformer à CEI 60947-2
100 kA à 440 V CA 50/60 Hz se conformer à CEI 60947-2
[icw] rated short-time withstand current 100 kA 0,5 s se conformer à CEI 60947-2
100 kA 1s se conformer à CEI 60947-2
75 kA 3 s se conformer à CEI 60947-2
Handle front plate colour 352 mm
[uimp] rated impulse withstand voltage 12 kV se conformer à CEI 60947-2
mechanical life 15000 cycle avec maintenance préventive périodique se conformer à CEI 60947-2
mode d'installation Fixe
electrical life AC-23A: 5000 cycle 440 V CA 50/60 Hz au courant nominal se conformer à CEI 60947-3
AC-3: 6000 cycle 440 V CA 50/60 Hz au courant nominal se conformer à CEI 60947-3
circuit breaker ct rating 3200 A
maximum outage time 25 ms
width (w) 537 mm
network frequency 50/60 Hz
depth 300 mm
mounting bracket Platine de base
Rails
Network type CA
maximum closing time 70 ms
order type Bouton-poussoir
Poles description 4P
Environment
degree of pollution 3 se conformer à CEI 60947-1
ip degree of protection IP30
product certificates certificat CEI CE
operating ambient temperature -25…70 °C
standards CEI 60947-1
CEI 60947-2
storage room temperature -40…85 °C