All categories
Compare Cart

LV563505 - Circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 630 A rating ETS 2.3 electronic trip unit, 3P 3d - Schneider Electric

Expected in 2-4 weeks
LV563505 - Circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 630 A rating ETS 2.3 electronic trip unit, 3P 3d - Schneider Electric - Circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 630 A rating ETS 2.3 electronic trip unit, 3P 3d - Schneider Electric - 0
LV563505 - Circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 630 A rating ETS 2.3 electronic trip unit, 3P 3d - Schneider Electric
774,64 € excl. VAT
945,06 € incl. VAT
Text About:
Circuit breaker EasyPact CVS630F, 36 kA at 415 VAC, 630 A rating ETS 2.3 electronic trip unit, 3P 3d - Schneider Electric
945,06 €
SPECIFICATIONS
Main
Device short name CVS630F
Range EasyPact
Earth leakage protection (vigi add on) Without
Protected poles description 3D
Product Name EasyPact CVS
Trip unit name ETS 2.3
Trip unit technology Electronic
Trip unit rating 630 A at 40 °C
Trip unit protection functions LSoI
Complementary
[in] rated current 630 A at 40 °C
compatibility code CVS630
[ics] rated service breaking capacity 40 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
36 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2
23 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2
Control type Toggle
Product certifications GOST
IEC
[isd] short-time pick-up adjustment range 1.5...10 x Ir
Connection pitch 45 mm
Handle front plate colour 255 mm
Product or component type Circuit breaker
[uimp] rated impulse withstand voltage 8 kV conforming to EN/IEC 60947-2
[tr] long-time delay adjustment range 5.5 s at 7.2 x Ir
8 s at 6 x Ir
200 s at 1.5 x Ir
Connections - terminals Screw connection
Breaking capacity code F
Contact position indication Yes
Device application Distribution
Electrical shock protection class Class II
width (w) 140 mm
network frequency 50/60 Hz
thermal memory Yes
Mounting mode Fixed
Net weight 5.2 kg
Downside connection Front
Mounting support Backplate
depth 110 mm
mechanical durability 15000 cycles
electrical durability 4000 cycles 415 V In conforming to IEC 60947-2
Network type AC
Pollution degree 3 conforming to IEC 60664-1
Instantaneous pick-up adjustment range 11 x In
Instantaneous pick-up adjustment type ii Fixed
Long time delay adjustment type Fixed
Long time pick-up adjustment range 250...630 A
Long time pick-up adjustment type ir Adjustable 9 settings
Poles description 3P
Upside connection Front
Short-time delay adjustment type Fixed
Utilisation category Category A
Short-time pick-up adjustment type isd Adjustable 9 settings
Protection type Short time short-circuit protection
Instantaneous short-circuit protection
Overload protection (long time)
Environment
Ambient air temp for storage/transportation -50…85 °C
ip degree of protection IP40
ambient air temperature for operation -25…70 °C
standards EN 60947-2
IEC 60947-2
Recently viewed
774,64 € excl. VAT
945,06 € incl. VAT
Expected in 2-4 weeks