All categories
Compare Cart

LV433484 - Circuit breaker ComPact NSX250HB1, 75 kA at 690 VAC, TMD trip unit 250 A, 3 poles 3d - Schneider Electric

Expected in 2-4 weeks
LV433484 - Circuit breaker ComPact NSX250HB1, 75 kA at 690 VAC, TMD trip unit 250 A, 3 poles 3d - Schneider Electric - Circuit breaker ComPact NSX250HB1, 75 kA at 690 VAC, TMD trip unit 250 A, 3 poles 3d - Schneider Electric - 0
LV433484 - Circuit breaker ComPact NSX250HB1, 75 kA at 690 VAC, TMD trip unit 250 A, 3 poles 3d - Schneider Electric
1 539,33 €
1 539,33 € incl. VAT
Text About:
Circuit breaker ComPact NSX250HB1, 75 kA at 690 VAC, TMD trip unit 250 A, 3 poles 3d - Schneider Electric
1 539,33 €
SPECIFICATIONS
Main
Device short name NSX250HB1
Range ComPact
circuit breaker mounting mode Fixed
Protected poles description 3t
Product Name ComPact NSX
Trip unit name TM-D
Trip unit technology Thermal-magnetic
Trip unit rating 250 A at 40 °C
[ui] rated insulation voltage 800 V AC 50/60 Hz
Trip unit protection functions LI
performance level HB1 75 kA 690 V AC
Complementary
[in] rated current 250 A at 40 °C
[ue] rated operational voltage 690 V AC 50/60 Hz
[ics] rated service breaking capacity 85 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2
80 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2
75 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2
Control type Toggle
depth (d) 86 mm
Product certifications Marine
EAC
CCC
[ir] long-time protection pick-up adjustment range 0.7...1 x In
Connection pitch 35 mm
Handle front plate colour 161 mm
Product or component type Circuit breaker
[isd] short-time protection pick-up adjustment range 5...10 x In
[uimp] rated impulse withstand voltage 8 kV
[tr] long-time delay adjustment range 120…400 s at 1.5 x In
15 s at 6 x Ir
Device application Distribution
Electrical shock protection class Class II
width (w) 105 mm
network frequency 50/60 Hz
Ik degree of protection IK07 conforming to IEC 62262
long-time pick-up adjustment type ir (thermal protection) Adjustable
Net weight 2.4 kg
long-time protection delay adjustment type tr Fixed
Downside connection Front
number of slots for electrical auxiliaries 5 slot(s)
Earth-leakage protection Without
Mounting support Backplate
mechanical durability 20000 cycles
electrical durability 5000 cycles at 690 V In
10000 cycles at 690 V In/2
10000 cycles at 440 V In
20000 cycles at 440 V In/2
Network type AC
Pollution degree 3 conforming to IEC 60664-1
short-time protection delay adjustment type tsd Fixed
short-time protection pick-up adjustment type isd Adjustable
Suitability for isolation Yes conforming to EN/IEC 60947-2
Poles description 3P
Upside connection Front
Utilisation category Category A
Protection type L : for overload protection (thermal)
I : for short-circuit protection (magnetic)
Environment
Ambient air temp for storage/transportation -50…85 °C
ip degree of protection IP40 conforming to IEC 60529
operating altitude 0...2000 m without derating
2000 m...5000 m with derating
Range of product ComPact NSX100...250
ambient air temperature for operation -25…70 °C
overvoltage category Class II
standards EN/IEC 60947
relative humidity 0…95 %
Recently viewed
1 539,33 €
1 539,33 € incl. VAT
Expected in 2-4 weeks