All categories
Compare Cart

LUCMT1BL - Multifunction control unit, TeSys Ultra, 1P/3P, 0.35 to 1.05A, 690VAC, protection & diagnostic, class 5 to 30, 24VDC coil - Schneider Electric

Expected in 2-4 weeks
LUCMT1BL - Multifunction control unit, TeSys Ultra, 1P/3P, 0.35 to 1.05A, 690VAC, protection & diagnostic, class 5 to 30, 24VDC coil - Schneider Electric - Multifunction control unit, TeSys Ultra, 1P/3P, 0.35 to 1.05A, 690VAC, protection & diagnostic, class 5 to 30, 24VDC coil - Schneider Electric - 0
LUCMT1BL - Multifunction control unit, TeSys Ultra, 1P/3P, 0.35 to 1.05A, 690VAC, protection & diagnostic, class 5 to 30, 24VDC coil - Schneider Electric
598,78 € excl. VAT
730,52 € incl. VAT
Text About:
Multifunction control unit, TeSys Ultra, 1P/3P, 0.35 to 1.05A, 690VAC, protection & diagnostic, class 5 to 30, 24VDC coil - Schneider Electric
730,52 €
SPECIFICATIONS
Main
Device short name LUCM
product specific application Most sophisticated control and protection requirements, with display
Range TeSys
[uc] control circuit voltage 24 V DC
thermal overload class Class 5…30 - frequency limit: 50…60 Hz - temperature compensation: -25…55 °C conforming to IEC 60947-6-2
Class 5…30 - frequency limit: 50…60 Hz - temperature compensation: -25…55 °C conforming to UL 508
user language English - setting factory setting
English, French, German, Italian, Spanish - setting settable
Rated motor current adjustment range 0.35…1.05 A
[ui] rated insulation voltage 250 V conforming to IEC 60947-6-2
250 V conforming to UL 60947-4-1
250 V conforming to CSA C22.2 No 60947-4-1
main function available Overload, no-load running
Protection against phase failure and phase imbalance
Protection against overload and short-circuit
Manual or automatic reset
Earth fault protection
Log function
Differentiation of thermal overload and magnetic fault
Protection function alarm
Monitoring function, indication of main motor parameters
reset Automatic reset - setting: setting range
Manual - setting: factory setting
Manual - setting: setting range
Remote reset - setting: setting range
Complementary
product compatibility Power base LUTM
compatibility code LUCM
Product certifications UL
CSA
Handle front plate colour 66 mm
Product or component type Multifunction control unit
[uimp] rated impulse withstand voltage 4 kV conforming to IEC 60947-6-2
Device application Motor control
Motor protection
Fixing mode Plug-in (front face)
Control circuit voltage limits 20...28 V for DC circuit 24 V in operation
14.5 V for DC circuit 24 V drop-out
information displayed Average current (factory setting)
Average current (settable)
Cause of last 5 faults (settable)
Current in phase (settable)
Earth leakage current (settable)
Phase imbalance (settable)
Thermal state of motor (settable)
width (w) 45 mm
network frequency 40...60 Hz
Heat dissipation 2 W for control circuit
Net weight 0.175 kg
physical interface RS485 multidrop - connector(s): RJ45 - location: front panel - communication protocol: Modbus RTU 19200 bit/s
Immunity to microbreaks 3 ms
depth 60 mm
Load type 3-phase motor - cooling: self-cooled - setting factory setting
3-phase motor - cooling: self-cooled, force cooled - setting settable
Single-phase motor - cooling: self-cooled, force cooled - setting settable
Messages display capacity 2 lines of 12 characters - display LCD - English - accuracy +/- 5 % - resolution 1 % of Ir
2 lines of 12 characters - display LCD - French - accuracy +/- 5 % - resolution 1 % of Ir
2 lines of 12 characters - display LCD - German - accuracy +/- 5 % - resolution 1 % of Ir
2 lines of 12 characters - display LCD - Italian - accuracy +/- 5 % - resolution 1 % of Ir
2 lines of 12 characters - display LCD - Spanish - accuracy +/- 5 % - resolution 1 % of Ir
operating time 35 ms opening for control circuit
70 ms closing for control circuit
Immunity to radioelectric fields 10 V conforming to IEC 61000-4-6
Phase failure sensitivity Yes
Tripping threshold 14.2 x Ir +/- 20 %
Resistance to electrostatic discharge 8 kV level 3 in open air conforming to IEC 61000-4-2
8 kV level 4 on contact conforming to IEC 61000-4-2
Shock resistance 10 gn power poles open conforming to IEC 60068-2-27
15 gn power poles closed conforming to IEC 60068-2-27
Return time <= 200 ms
Time before reset 1…1000 s - reset manual or automatic reset - setting settable
120 s - reset manual - setting factory setting
Utilisation category AC-41
AC-44
AC-43
Typical current consumption 130 mA at 24 V DC I maximum while closing
60 mA at 24 V DC I rms sealed
Environment
Ambient air temp for storage/transportation -40…85 °C
ip degree of protection IP20 front panel and wired terminals conforming to IEC 60947-1
IP20 other faces conforming to IEC 60947-1
IP40 front panel outside connection zone conforming to IEC 60947-1
operating altitude 2000 m
Range of product TeSys Ultra
ambient air temperature for operation -25…60 °C
standards EN 60947-6-2
IEC 60947-6-2
UL 508
CSA C22.2 No 14
fire resistance 960 °C parts supporting live components conforming to IEC 60695-2-12
650 °C conforming to IEC 60695-2-12
immunity to voltage dips 70 % / 500 ms conforming to IEC 61000-4-11
resistance to radiated fields 10 V/m 3 conforming to IEC 61000-4-3
vibration resistance 2 gn, 5…300 Hz, power poles open conforming to IEC 60068-2-6
4 gn, 5…300 Hz, power poles closed conforming to IEC 60068-2-6
protective treatment TH conforming to IEC 60068
resistance to fast transients 2 kV class 3 serial link conforming to IEC 61000-4-4
4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Recently viewed
598,78 € excl. VAT
730,52 € incl. VAT
Expected in 2-4 weeks