All categories
Compare Cart

LUB120 - Non reversing power base, TeSys Ultra, 3P, 1NO + 1NC, 12A, 690V, Advanced power base - Schneider Electric

Pending restock
LUB120 - Non reversing power base, TeSys Ultra, 3P, 1NO + 1NC, 12A, 690V, Advanced power base - Schneider Electric - Non reversing power base, TeSys Ultra, 3P, 1NO + 1NC, 12A, 690V, Advanced power base - Schneider Electric - 0
LUB120 - Non reversing power base, TeSys Ultra, 3P, 1NO + 1NC, 12A, 690V, Advanced power base - Schneider Electric
54,90 € excl. VAT
68,08 € incl. VAT
Text About:
Non reversing power base, TeSys Ultra, 3P, 1NO + 1NC, 12A, 690V, Advanced power base - Schneider Electric
68,08 €
SPECIFICATIONS
Main
Device short name LUB
Range TeSys
[uc] control circuit voltage 24 V AC 50/60 Hz
24 V DC
48...72 V AC 50/60 Hz
48...72 V DC
110...240 V AC 50/60 Hz
110...220 V DC
Product Name TeSys Ultra
[ui] rated insulation voltage 690 V conforming to IEC 60947-6-2 (pollution degree 3)
600 V conforming to UL 60947-4-1
600 V conforming to CSA C22.2 No 60947-4-1
Complementary
[ie] rated operational current 12 A at <= 440 V
12 A at 500 V
9 A at 690 V
[ue] rated operational voltage 690 V AC for power circuit
compatibility code LUB
[ics] rated service breaking capacity 50 kA at 230 V
50 kA at 440 V
10 kA at 500 V
4 kA at 690 V
[ith] conventional thermal current 12 A
Product certifications CE
UL
CSA
CCC
EAC
ASEFA
ATEX
Marine
Handle front plate colour 154 mm
Product or component type Non reversing power base
tightening torque Control circuit: 0.8…1.2 N.m flat screwdriver 5 mm
Control circuit: 0.8…1.2 N.m Philips no 1 screwdriver 5 mm
Power circuit: 1.9…2.5 N.m flat screwdriver 6 mm
Power circuit: 1.9…2.5 N.m Philips No 2 screwdriver 6 mm
Power circuit: 1.9…2.5 N.m pozidriv No 2 screwdriver 6 mm
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-6-2
Auxiliary contact composition 1 NO + 1 NC
Connections - terminals Power circuit: screw clamp terminals 1 cable(s) 1…10 mm² rigid
Power circuit: screw clamp terminals 1 cable(s) 1…6 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 2.5…10 mm² flexible without cable end
Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² flexible with cable end
Power circuit: screw clamp terminals 2 cable(s) 1…6 mm² rigid
Power circuit: screw clamp terminals 2 cable(s) 1.5…6 mm² flexible without cable end
Control circuit: without connection
Auxiliary contacts type type linked contacts (1 NO + 1 NC) conforming to IEC 60947-4-1
type mirror contact (1 NC) conforming to IEC 60947-1
Device application Motor control
Motor protection
Fixing mode Clipped (DIN rail)
Screw-fixed (plate)
width (w) 45 mm
network frequency 40...60 Hz
Heat dissipation 2 W for control circuit with LUCA, LUCB, LUCC, LUCD
1.7 W for control circuit with LUCM
Net weight 0.865 kg
Immunity to microbreaks 3 ms for control circuit
depth 126 mm
mechanical durability 15 Mcycles
Maximum operating rate 3600 cyc/h
operating time 35 ms opening with LUCA, LUCB, LUCC, LUCD, LUCM for control circuit
50 ms at >= 72 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
60 ms at 48 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
70 ms at 24 V closing with LUCA, LUCB, LUCC, LUCD for control circuit
75 ms closing with LUCM for control circuit
Immunity to radioelectric fields 10 V conforming to IEC 61000-4-6
Resistance to electrostatic discharge 8 kV level 3 in open air conforming to IEC 61000-4-2
8 kV level 4 on contact conforming to IEC 61000-4-2
Shock resistance 10 gn power poles open conforming to IEC 60068-2-27
15 gn power poles closed conforming to IEC 60068-2-27
Suitability for isolation Yes
Poles description 3P
Safe separation of circuit 400 V SELV between the control and auxiliary circuits conforming to IEC 60947-1 appendix N
400 V SELV between the control or auxiliary circuit and the main circuit conforming to IEC 60947-1 appendix N
Utilisation category AC-43
AC-44
AC-41
Typical current consumption 130 mA at 24 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
140 mA at 24 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
150 mA at 24 V DC I maximum while closing with LUCM
280 mA at 110...220 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA at 110...240 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA at 48...72 V AC I maximum while closing with LUCA, LUCB, LUCC, LUCD
280 mA at 48...72 V DC I maximum while closing with LUCA, LUCB, LUCC, LUCD
35 mA at 110...220 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
35 mA at 110...240 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
35 mA at 48...72 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
35 mA at 48...72 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
60 mA at 24 V DC I rms sealed with LUCA, LUCB, LUCC, LUCD
70 mA at 24 V AC I rms sealed with LUCA, LUCB, LUCC, LUCD
70 mA at 24 V DC I rms sealed with LUCM
Safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Environment
Ambient air temp for storage/transportation -40…85 °C
ip degree of protection IP20 conforming to IEC 60947-1 (front panel and wired terminals)
IP20 conforming to IEC 60947-1 (other faces)
IP40 conforming to IEC 60947-1 (front panel outside connection zone)
operating altitude 2000 m
ambient air temperature for operation -25…60 °C with LUCM
-25…70 °C with LUCA, LUCB, LUCC, LUCD
Non-dissipating shock wave 1 kV serial mode 24...240 V AC conforming to IEC 60947-6-2
1 kV serial mode 48...220 V DC conforming to IEC 60947-6-2
2 kV common mode 24...240 V AC conforming to IEC 60947-6-2
2 kV common mode 48...220 V DC conforming to IEC 60947-6-2
standards EN 60947-6-2
IEC 60947-6-2
UL 60947-4-1, with phase barrier
CSA C22.2 No 60947-4-1, with phase barrier
fire resistance 960 °C parts supporting live components conforming to IEC 60695-2-12
650 °C conforming to IEC 60695-2-12
immunity to voltage dips 70 % / 500 ms conforming to IEC 61000-4-11
resistance to radiated fields 10 V/m 3 conforming to IEC 61000-4-3
vibration resistance 2 gn (f= 5…300 Hz) power poles open conforming to IEC 60068-2-27
4 gn (f= 5…300 Hz) power poles closed conforming to IEC 60068-2-27
protective treatment TH conforming to IEC 60068
resistance to fast transients 2 kV class 3 serial link conforming to IEC 61000-4-4
4 kV class 4 all circuits except for serial link conforming to IEC 61000-4-4
Q&A and product info

Contact Us

Professional sales of electrical equipment in Estonia, Latvia, Lithuania, and Finland. Certified low-voltage components, circuit breakers, contactors, and industrial automation solutions. Same-day quotations and fast delivery across the Baltics and Finland.

Baltelec
+372 5326 4976

Mon–Fri 9:00–17:00

info@baltelec.eu

Response within 2 hours

LUB120 is a industrial TeSyS Ultra product designed for professionals. BaltElec specializes in volume-based sales and product distribution in Estonia, Latvia, Lithuania, and Finland.

  • Authentic Schneider Electric product, certificates and compliance documents available.
  • Project pricing – request a quote for larger quantities (MOQ may apply).
  • Efficient logistics across the Baltics and Finland; cooperation with logistics partners.
  • Technical support and selection assistance based on your requirements.

Pricing: Request a project quote. The price depends on quantity, delivery, and payment terms.

TeSyS Ultra specifications may vary by configuration. For an exact match, please send us your requirements or check the technical data sheet.

FAQ for LUB120 - Schneider Electric

Recently viewed
LUB120 - Schneider Electric
Non reversing power base, TeSys Ultra, 3P, 1NO + 1NC, 12A, 690V, Advanced power base
54,90 € excl. VAT
68,08 € incl. VAT
Pending restock