All categories
Compare Cart

LTMR08EBD - Motor controller, TeSys T, Motor Management, Ethernet/IP, Modbus/TCP, 6 logic inputs, 3 logic outputs, 0.4 to 8A, 24VDC - Schneider Electric

Expected in 2-4 weeks
LTMR08EBD - Motor controller, TeSys T, Motor Management, Ethernet/IP, Modbus/TCP, 6 logic inputs, 3 logic outputs, 0.4 to 8A, 24VDC - Schneider Electric - Motor controller, TeSys T, Motor Management, Ethernet/IP, Modbus/TCP, 6 logic inputs, 3 logic outputs, 0.4 to 8A, 24VDC - Schneider Electric - 0
LTMR08EBD - Motor controller, TeSys T, Motor Management, Ethernet/IP, Modbus/TCP, 6 logic inputs, 3 logic outputs, 0.4 to 8A, 24VDC - Schneider Electric
1 115,33 € excl. VAT
1 360,70 € incl. VAT
Text About:
Motor controller, TeSys T, Motor Management, Ethernet/IP, Modbus/TCP, 6 logic inputs, 3 logic outputs, 0.4 to 8A, 24VDC - Schneider Electric
1 360,70 €
SPECIFICATIONS
Main
Device short name LTMR
Measurement current 0.4…8 A
Range TeSys
Product Name TeSys T
[ui] rated insulation voltage 690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
Complementary
compatibility code LTMR
Product certifications CCC
ABS
C-Tick
NOM
CSA
RMRoS
RINA
UL
BV
KERI
DNV
GL
EAC
LROS (Lloyds register of shipping)
ATEX
Connection pitch 5.08 mm
Handle front plate colour 61 mm
Product or component type Motor controller
tightening torque Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
[uimp] rated impulse withstand voltage 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
[us] rated supply voltage 24 V DC
Current consumption 56...127 mA
Connections - terminals Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
current state 0 guaranteed Logic input: < 5 V and <= 15 mA for 5 ms
Associated fuse rating 4 A gG for output
0.5 A gG for control circuit
Bus type Ethernet IEEE 802.3 interface, addressing 0...159, transmission rate 10...100 Mbit/s, RJ45 with 2 shielded twisted pairs
current state 1 guaranteed Logic input: < 15 V and 2...15 mA for 15 ms
Device application Equipment monitoring and control
Contacts type and composition 1 NO + 1 NC fault signal
3 NO
input current 7 mA
Load current 5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
width (w) 91 mm
mechanical robustness Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
supply voltage limits 20.4…26.24 V DC
Net weight 0.53 kg
measurement accuracy 5...15 % earth fault current internal measurement
1 % voltage (100...830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
1 % current
5 % active and reactive power
communication port protocol Modbus TCP/EtherNet/IP
depth 122.5 mm
Pollution degree 3
Maximum operating rate 1800 cyc/h
Logic input number 6
Maximum output switching frequency 2 Hz
Metering type Average current Iavg
Temperature
Earth-fault current
Phase current I1, I2, I3 RMS
Imbalance current
Network and machine diagnosis type Event recording
Remaining operating time before overload tripping
Trip context information
Waiting time after overload tripping
Running hours counter/operating time
Trip history information
Fault recording
Starting current and time
Phase fault and earth fault trip counters
Motor control command recording
Permissible power 480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
Short-circuit withstand 100 kA conforming to EN/IEC 60947-4-1
Protection type Phase failure
Locked rotor
Earth-leakage protection
Thermal protection
Overload
Phase unbalance
Reverse polarity protection
Power factor variation
Overload (long time)
Thermal overload protection
Load fluctuation
Web services Web server
Environment
Ambient air temp for storage/transportation -40…80 °C
ip degree of protection IP20
operating altitude <= 2000 m without derating
ambient air temperature for operation -20…60 °C
electromagnetic compatibility Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
overvoltage category III
standards IACS E10
UL 508
CSA C22.2 No 14
EN 60947-4-1
IEC 60947-4-1
fire resistance 650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
protective treatment 12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
Recently viewed
1 115,33 € excl. VAT
1 360,70 € incl. VAT
Expected in 2-4 weeks