All categories
Compare Cart

LTMR08DFM - Motor controller, TeSys T, Motor Management, DeviceNet, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 100 to 240VAC - Schneider Electric

Expected in 2-4 weeks
LTMR08DFM - Motor controller, TeSys T, Motor Management, DeviceNet, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 100 to 240VAC - Schneider Electric - Motor controller, TeSys T, Motor Management, DeviceNet, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 100 to 240VAC - Schneider Electric - 0
LTMR08DFM - Motor controller, TeSys T, Motor Management, DeviceNet, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 100 to 240VAC - Schneider Electric
882,59 € excl. VAT
1 076,76 € incl. VAT
Text About:
Motor controller, TeSys T, Motor Management, DeviceNet, 6 logic inputs, 3 relay logic outputs, 0.4 to 8A, 100 to 240VAC - Schneider Electric
1 076,76 €
SPECIFICATIONS
Main
Device short name LTMR
Measurement current 0.4…8 A
Range TeSys
Product Name TeSys T
[ui] rated insulation voltage 690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
Complementary
compatibility code LTMR
Product certifications KERI
LROS (Lloyds register of shipping)
CSA
ATEX
UL
DNV
C-Tick
RMRoS
CCC
RINA
ABS
EAC
GL
NOM
BV
Connection pitch 5.08 mm
Handle front plate colour 61 mm
Product or component type Motor controller
tightening torque Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
[uimp] rated impulse withstand voltage 4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV communication circuit conforming to EN/IEC 60947-4-1
[us] rated supply voltage 100...240 V AC 50/60 Hz
Current consumption 8...62.8 mA
Connections - terminals Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
current state 0 guaranteed Logic input: 0...40 V and <= 15 mA for 25 ms
Associated fuse rating 4 A gG for output
0.5 A gG for control circuit
Bus type DeviceNet ISO 1198 interface, addressing 1...64, transmission rate 125...500 kbit/s, terminal block with 4 twisted shielded pairs cable
current state 1 guaranteed Logic input: 79...264 V and >= 2 mA for 25 ms
Device application Equipment monitoring and control
Contacts type and composition 1 NO + 1 NC fault signal
3 NO
input current 3.1 mA at 100 V
7.5 mA at 240 V
Load current 5 A at 250 V AC for logic output
5 A at 30 V DC for logic output
width (w) 91 mm
mechanical robustness Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
supply voltage limits 93.5…264 V AC
Net weight 0.53 kg
measurement accuracy 5...15 % earth fault current internal measurement
1 % voltage (100...830 V)
3 % power factor
5 % earth fault current external measurement
+/- 30 min/year internal clock
0,02 temperature
1 % current
5 % active and reactive power
communication port protocol DeviceNet
depth 122.5 mm
Pollution degree 3
Maximum operating rate 1800 cyc/h
Logic input number 6
Maximum output switching frequency 2 Hz
Metering type Imbalance current
Earth-fault current
Average current Iavg
Temperature
Phase current I1, I2, I3 RMS
Network and machine diagnosis type Running hours counter/operating time
Starting current and time
Fault recording
Trip history information
Trip context information
Phase fault and earth fault trip counters
Motor control command recording
Event recording
Waiting time after overload tripping
Remaining operating time before overload tripping
Permissible power 480 VA (AC-15), Ie = 2 A, 500000 cycles (output)
30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)
Short-circuit withstand 100 kA conforming to EN/IEC 60947-4-1
Protection type Thermal overload protection
Phase failure
Overload
Load fluctuation
Power factor variation
Overload (long time)
Earth-leakage protection
Reverse polarity protection
Thermal protection
Phase unbalance
Locked rotor
Web services Web server
Environment
Ambient air temp for storage/transportation -40…80 °C
ip degree of protection IP20
operating altitude <= 2000 m without derating
ambient air temperature for operation -20…60 °C
electromagnetic compatibility Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5
Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
overvoltage category III
standards UL 508
IACS E10
CSA C22.2 No 14
IEC 60947-4-1
EN 60947-4-1
fire resistance 650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
protective treatment 12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
Recently viewed
882,59 € excl. VAT
1 076,76 € incl. VAT
Expected in 2-4 weeks