All categories
Compare Cart

LTMEV40BD - Motor Management, TeSys T, motor controller, extension module, 4 inputs, for LTMR controller, 24 VDC - Schneider Electric

Pending restock
LTMEV40BD - Motor Management, TeSys T, motor controller, extension module, 4 inputs, for LTMR controller, 24 VDC - Schneider Electric - Motor Management, TeSys T, motor controller, extension module, 4 inputs, for LTMR controller, 24 VDC - Schneider Electric - 0
LTMEV40BD - Motor Management, TeSys T, motor controller, extension module, 4 inputs, for LTMR controller, 24 VDC - Schneider Electric
258,58 € excl. VAT
320,64 € incl. VAT
Text About:
Motor Management, TeSys T, motor controller, extension module, 4 inputs, for LTMR controller, 24 VDC - Schneider Electric
320,64 €
SPECIFICATIONS
Main
Device short name LTME
Range TeSys
Product Name TeSys T
[ui] rated insulation voltage 690 V conforming to EN/IEC 60947-1
690 V conforming to CSA C22.2 No 14
690 V conforming to UL 508
Complementary
compatibility code LTME
range compatibility TeSys (TeSys T) LTMR motor controller
Product certifications UL
NOM
ATEX
BV
CSA
EAC
RINA
LROS (Lloyds register of shipping)
DNV
ABS
GL
KERI
RMRoS
C-Tick
CCC
Connection pitch 5.08 mm
Handle front plate colour 61 mm
Product or component type Extension module
tightening torque Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm
[uimp] rated impulse withstand voltage 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1
0.8 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1
Connections - terminals Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end
Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end
Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end
current state 0 guaranteed Logic input: < 5 V and <= 15 mA for 5 ms
current state 1 guaranteed Logic input: < 15 V and 2...15 mA for 15 ms
Device application Equipment monitoring and control
Contacts type and composition Without
input current 7 mA
width (w) 45 mm
mechanical robustness Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27
Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6
Net weight 0.21 kg
measurement accuracy 1 % voltage (100...830 V)
3 % power factor
5 % active and reactive power
depth 120.7 mm
Pollution degree 3
Maximum operating rate 1800 cyc/h
Logic input number 4
Maximum output switching frequency 2 Hz
Metering type Voltage U21, U32, U13, V1, V2, V3
Imbalance voltage
Frequency
Calculated active and reactive energy (+/- W.h, +/- VAR.h)
Reactive power Q, Q1, Q2, Q3
Power factor
Active power P, P1, P2, P3
Supply Via the controller
Environment
Ambient air temp for storage/transportation -40…80 °C
ip degree of protection IP20
operating altitude <= 2000 m without derating
ambient air temperature for operation -20…60 °C
electromagnetic compatibility Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2
Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4
Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4
Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6
Control circuit: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5
Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5
Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5
Voltage inputs: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5
Voltage inputs: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5
overvoltage category III
standards IEC 60947-4-1
UL 508
EN 60947-4-1
IACS E10
CSA C22.2 No 14
fire resistance 650 °C conforming to EN/IEC 60695-2-12
960 °C conforming to UL 94
protective treatment 12 x 24 hour cycles conforming to EN/IEC 60068-2-30
48 h conforming to EN/IEC 60070-2-11
TH conforming to EN/IEC 60068
Q&A and product info

Contact Us

Professional sales of electrical equipment in Estonia, Latvia, Lithuania, and Finland. Certified low-voltage components, circuit breakers, contactors, and industrial automation solutions. Same-day quotations and fast delivery across the Baltics and Finland.

Baltelec
+372 5326 4976

Mon–Fri 9:00–17:00

info@baltelec.eu

Response within 2 hours

LTMEV40BD Schneider Electric is a industrial TeSyS LT product designed for companies. BaltElec specializes in wholesale and product distribution in Estonia, Latvia, Lithuania, and Finland.

  • Original Schneider Electric product, documentation available on request.
  • Volume-based pricing – request a quote for larger quantities (MOQ may apply).
  • Efficient logistics across the Baltics and Finland; cooperation with logistics partners.
  • Technical support and application suitability advice based on your requirements.

Pricing: Request a project quote. The price depends on quantity, delivery, and payment terms.

TeSyS LT specifications may vary by configuration. For an exact match, please send us your application details or check the technical data sheet.

FAQ for LTMEV40BD - Schneider Electric

Recently viewed
LTMEV40BD - Schneider Electric
Motor Management, TeSys T, motor controller, extension module, 4 inputs, for LTMR controller, 24 VDC
258,58 € excl. VAT
320,64 € incl. VAT
Pending restock