All categories
Compare Cart

LRD3363 - TeSys Deca thermal overload relays 63...80 A class 10A - Schneider Electric

Expected in 2-4 weeks
LRD3363 - TeSys Deca thermal overload relays  63...80 A  class 10A - Schneider Electric - TeSys Deca thermal overload relays  63...80 A  class 10A - Schneider Electric - 0
LRD3363 - TeSys Deca thermal overload relays 63...80 A class 10A - Schneider Electric
98,74 € excl. VAT
120,46 € incl. VAT
Text About:
TeSys Deca thermal overload relays 63...80 A class 10A - Schneider Electric
120,46 €
SPECIFICATIONS
Main
Device short name LRD
Range TeSys
thermal overload class Class 10A conforming to IEC 60947-4-1
Product Name TeSys LRD
TeSys Deca
[ui] rated insulation voltage Power circuit: 1000 V conforming to IEC 60947-4-1
Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Relay application Motor protection
thermal protection adjustment range 63…80 A
Complementary
product compatibility LC1D80
LC1D95
[ue] rated operational voltage 1000 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1
[ith] conventional thermal current 5 A for signalling circuit
Control type Red push-button: stop
Blue push-button: reset
Product certifications IEC
UL
CSA
CCC
EAC
ATEX INERIS
UKCA
Handle front plate colour 81 mm
Product or component type Differential thermal overload relay
tightening torque Control circuit: 1.7 N.m - on screw clamp terminals
Power circuit: 9 N.m - on screw clamp terminals
[uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947-1
Auxiliary contact composition 1 NO + 1 NC
temperature compensation -20…60 °C
Connections - terminals Power circuit: screw clamp terminals 1 cable(s) 4…35 mm² flexible without cable end
Power circuit: screw clamp terminals 1 cable(s) 4…35 mm² flexible with cable end
Power circuit: screw clamp terminals 1 cable(s) 4…35 mm² solid without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit
Permissible current 0.72 A at 500 V AC-15 for signalling circuit
0.06 A at 440 V DC-13 for signalling circuit
width (w) 70 mm
mechanical robustness Vibrations: 6 Gn conforming to IEC 60068-2-6
Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
network frequency 0...400 Hz
Flame retardance V1 conforming to UL 94
Net weight 0.51 kg
Mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactor
depth 115 mm
Network type DC
AC
dielectric strength 2.2 kV at 50 Hz conforming to IEC 60947-1
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Tripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -60…70 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP20 conforming to IEC 60529
ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1
standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495