SPECIFICATIONS
Main
Device short name LR3D
Range TeSys
TeSys Deca
thermal overload class Class 10A conforming to IEC 60947-4-1
Product Name TeSys LRD
TeSys Deca
[ui] rated insulation voltage Power circuit: 600 V conforming to CSA
Power circuit: 600 V conforming to UL
Power circuit: 690 V conforming to IEC 60947-4-1
Relay application Motor protection
thermal protection adjustment range 23…32 A
Complementary
product compatibility LC1D38
LC1D25
LC1D32
[ue] rated operational voltage 690 V AC 0...400 Hz for power circuit conforming to IEC 60947-4-1
[ith] conventional thermal current 5 A for signalling circuit
Control type Red push-button: stop
Blue push-button: reset
Product certifications IEC
UL
CSA
CCC
EAC
BV
RINA
DNV-GL
LROS (Lloyds register of shipping)
ATEX INERIS
UKCA
Connection pitch 17.5 mm
Handle front plate colour 66 mm
Product or component type Non differential thermal overload relay
tightening torque Control circuit: 1.7 N.m - on screw clamp terminals
Power circuit: 2.3 N.m - on lugs-ring terminals M4
[uimp] rated impulse withstand voltage 6 kV
Auxiliary contact composition 1 NO + 1 NC
temperature compensation -20…60 °C
Connections - terminals Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible without cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² flexible with cable end
Control circuit: screw clamp terminals 2 cable(s) 1…2.5 mm² solid without cable end
Power circuit: lugs-ring terminals
Associated fuse rating 4 A gG for signalling circuit
4 A BS for signalling circuit
Permissible current 1.5 A at 240 V AC-15 for signalling circuit
0.1 A at 250 V DC-13 for signalling circuit
width (w) 45 mm
mechanical robustness Vibrations: 6 Gn conforming to IEC 60068-2-6
Shocks: 15 Gn for 11 ms conforming to IEC 60068-2-7
network frequency 0...400 Hz
Flame retardance V1 conforming to UL 94
Net weight 0.124 kg
Mounting support Plate, with specific accessories
Rail, with specific accessories
Under contactor
depth 70 mm
Network type DC
AC
dielectric strength 1.89 kV at 50 Hz conforming to IEC 60947-1
Phase failure sensitivity Tripping current 130 % of Ir on two phase, the last one at 0
Tripping threshold 1.14 +/- 0.06 Ir conforming to IEC 60947-4-1
Environment
Ambient air temp for storage/transportation -60…70 °C
Climatic withstand conforming to IACS E10
ip degree of protection IP20 conforming to IEC 60529
ambient air temperature for operation -20…60 °C without derating conforming to IEC 60947-4-1
standards EN/IEC 60947-4-1
EN/IEC 60947-5-1
UL 60947-4-1
UL 60947-5-1
CSA C22.2 No 60947-4-1
CSA C22.2 No 60947-5-1
GB/T 14048.4
GB/T 14048.5
EN 50495
About this product

The LR3D326 - Thermal overload relay,TeSys Deca,23-32A,1NO+1NC,class 10A,lugs terminal,for unbalanced loads is devised to address the requirements of sector experts, such as system integrators, wiring experts, service providers, and equipment creators. LR3D326 furnishes remarkable durability and gain for technicians in the energy management industry. This Thermal overload relay,TeSys Deca,23-32A,1NO+1NC,class 10A,lugs terminal,for unbalanced loads and other TeSyS Deca Overload Relays from Schneider Electric can be ordered at the lowest cost and shipment duration through BALTELEC, a reliable dealer serving contractors in their purchasing needs.

Consumers who have procured Schneider Electric TeSyS Deca Overload Relays have regularly extolled the maker's dependability. It has been specified that the notable functionality of LR3D326 - Thermal overload relay,TeSys Deca,23-32A,1NO+1NC,class 10A,lugs terminal,for unbalanced loads extends to a multitude of functions. Its first-rate attributes make it fitting for multiple purposes, promoting success in your industrial, tertiary, and automation efforts.

Our experts dedicates in providing for industrial and tertiary professionals’ needs. We appreciate the specific specifications and requirements of our partners in the industry. By collaborating with Baltelec team, our customers gain access to the leading fees and lead time of top-tier products like LR3D326 - Thermal overload relay,TeSys Deca,23-32A,1NO+1NC,class 10A,lugs terminal,for unbalanced loads from Schneider Electric at a value-for-money price. Professional buyers with Baltelec account receive added discounts and dedicated support.

Act now and purchase LR3D326 - Thermal overload relay,TeSys Deca,23-32A,1NO+1NC,class 10A,lugs terminal,for unbalanced loads at our secure and intuitive platform. Don't delay in making this astute plan that ensures the paramount quality and covers the special specifications of suppliers like your business.

If you face any doubts or concerns about LR3D326 - Thermal overload relay,TeSys Deca,23-32A,1NO+1NC,class 10A,lugs terminal,for unbalanced loads or any other Schneider Electric products, communicate with us or refer to our Support section section below. We have brought together answers to usual problems to facilitate you further in making an enlightened decision about industrial and tertiary electrical components.

Remember, LR3D326 - Thermal overload relay,TeSys Deca,23-32A,1NO+1NC,class 10A,lugs terminal,for unbalanced loads from Schneider Electric is consistent, cost-effective, and premier to other producers in the TeSyS Deca Overload Relays category. Make it a part of your network at once. Take advantage of at BaltElec, your trusted partner for all your professional electrical equipment and automation needs.

In our Baltelec.eu virtual store you will find Thermal overload relay,TeSys Deca,23-32A,1NO+1NC,class 10A,lugs terminal,for unbalanced loads - LR3D326 worth 133.65 €, which will be a constant and cutting-edge solution for your necessities. This goods is invented by the Schneider Electric brand using the modern technologies and fulfills the top standards of assurance and capability. We give things from the TeSyS Deca Overload Relays category that combine resilience and efficacy, which is an exceptional decision for various purposes. Not minding of whether you call for appliances for small output or for qualified industrial operation, Thermal overload relay,TeSys Deca,23-32A,1NO+1NC,class 10A,lugs terminal,for unbalanced loads will be a trustworthy aide in your project.

Baltelec tries to make the buying process as easy and fast as possible for our buyers. We offer detailed summaries and high-quality visuals of Thermal overload relay,TeSys Deca,23-32A,1NO+1NC,class 10A,lugs terminal,for unbalanced loads so that you can make an versed choice. A team of virtuosos is always ready to help you with any questions in the TeSyS Deca Overload Relays section connected to the selection and use of goods. We are assured that Thermal overload relay,TeSys Deca,23-32A,1NO+1NC,class 10A,lugs terminal,for unbalanced loads will meet your requirements and become an crucial element of your equipment for just 133.65 €.

FAQ about Schneider Electric LR3D326:

Recently viewed
LR3D326 - Schneider Electric
Thermal overload relay,TeSys Deca,23-32A,1NO+1NC,class 10A,lugs terminal,for unbalanced loads
109,55 € excl. VAT
135,84 € incl. VAT
Expected in 2-4 weeks